Laserfiche WebLink
Environmental Checklist and City of Pleasanton–10x Genomics Project <br />Environmental Evaluation Initial Study/Mitigated Negative Declaration <br /> <br /> <br />110 FirstCarbon Solutions <br />Https://adecinnovations.sharepoint.com/sites/PublicationsSite/Shared Documents/Publications/Client (PN-JN)/2148/21480024/ISMND/wp/21480024 10x Genomics Project Full Screencheck ISMND.docx <br />generate approximately 60 dBA to 70 dBA Lmax at 50 feet. Conversation between two persons at a <br />distance of 3 to 5 feet apart would generate a noise level of 60 dBA Leq at 5 feet, or approximately 40 <br />dBA Leq as measured at 50 feet. In a reasonable worst-case scenario, assuming one parking movement <br />per parking stall within an hour, parking lot activities could result in intermittent noise levels ranging up <br />to 43 dBA Leq as measured at the property boundary of the nearest residential land use to the parking <br />lot, the multi-family residential receptor southwest of the project site. All operational noise level <br />calculations are provided in Appendix H. <br />It should be noted that these calculations and noise impact conclusions would also apply to the <br />proposed interim parking lot that would be located on the southern portion of the project site. <br />Thus, noise from these activities would not exceed the City’s most restrictive noise performance <br />standard (the standard for nighttime hours) of 65 dBA Leq as measured at the property boundary of <br />the nearest residential land use. Therefore, noise impacts from operational parking lot activity would <br />not result in a substantial permanent increase in ambient noise levels in excess of any of the noise <br />performance thresholds and would be less than significant. <br />Mechanical Equipment Operations <br />The proposed project would not utilize ventilation units larger or noisier than standard commercial- <br />grade ventilation systems; therefore, a reference noise level for typical rooftop mechanical <br />ventilation systems was used. Noise levels from typical rooftop mechanical ventilation equipment <br />are anticipated to range up to approximately 60 dBA Leq at a distance of 25 feet. The mechanical <br />ventilation equipment would be setback at least 10 feet from the edge of the proposed building’s <br />rooftop. Thus, rooftop mechanical ventilation systems could be located as close as 225 feet from the <br />property line of the nearest noise sensitive receptor, which are the multi-family residences on <br />Stoneridge Mall Road east of the project site. Based on distance attenuation, noise generated by <br />rooftop mechanical ventilation equipment would attenuate to approximately 41 dBA Leq as measured <br />at the property boundary of the nearest residential land use. All operational noise level calculations <br />are provided in Appendix H. <br />Thus, noise from mechanical equipment operations would not exceed the City’s most restrictive <br />noise performance standard (the standard for nighttime hours) of 65 dBA Leq as measured at the <br />property boundary of the nearest residential land use. <br />Truck Loading Activities <br />Noise would be generated by loading and unloading activities at the loading zones of the proposed <br />commercial buildings. Typical noise levels from truck loading and unloading activity can range from <br />70 dBA to 80 dBA Lmax as measured at 50 feet. A reasonable worst-case scenario assumes that <br />multiple trucks at the nearest loading bays to the nearest off-site receptor could produce simultaneous <br />loading and unloading activities within a single hour. <br />The proposed loading areas are positioned such that noise generated by loading and unloading <br />activities would be shielded by the intervening proposed buildings. This shielding would provide an <br />expected minimum 10 dBA reduction in truck loading noise levels. The nearest residential property line <br />is located approximately 350 feet from the nearest proposed loading area. Therefore, due to distance <br />attenuation and shielding reduction, truck loading and unloading activities would result in reasonable