My WebLink
|
Help
|
About
|
Sign Out
RES 211231 Exhibit A
City of Pleasanton
>
CITY CLERK
>
RESOLUTIONS
>
2020-present
>
2021
>
RES 211231 Exhibit A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/21/2021 4:00:01 PM
Creation date
6/21/2021 3:40:58 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
6/15/2021
DESTRUCT DATE
PERMANENT
Document Relationships
RES 211231
(Attachment)
Path:
\CITY CLERK\RESOLUTIONS\2020-present\2021
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
189
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Checklist and City of Pleasanton–10x Genomics Project <br />Environmental Evaluation Initial Study/Mitigated Negative Declaration <br /> <br /> <br />114 FirstCarbon Solutions <br />Https://adecinnovations.sharepoint.com/sites/PublicationsSite/Shared Documents/Publications/Client (PN-JN)/2148/21480024/ISMND/wp/21480024 10x Genomics Project Full Screencheck ISMND.docx <br />b) Generation of excessive groundborne vibration or groundborne noise levels? <br />Less than significant impact. A significant impact would occur if the proposed project would <br />generate groundborne vibration or groundborne noise levels in excess of established standards. The <br />City of Pleasanton has not adopted criteria for groundborne vibration impacts. Therefore, for <br />purposes of this analysis, the Federal Transit Administration (FTA’s ) vibration impact criteria are <br />utilized. The FTA has established industry accepted standards for vibration impact criteria and impact <br />assessment. These guidelines are published in its Transit Noise and Vibration Impact Assessment <br />Manual.91 <br />Groundborne noise is an effect of groundborne vibration and only exists indoors, since it is produced <br />from noise radiated from the motion of the walls and floors of a room and may also consist of the <br />rattling of windows or dishes on shelves. In general, if groundborne vibration levels do not exceed <br />levels considered to be perceptible, then groundborne noise levels would not be perceptible in most <br />interior environments. Therefore, this analysis focuses on determining exceedances of groundborne <br />vibration levels. <br />Although groundborne vibration can be felt outdoors, it is typically only an annoyance to people <br />indoors where the associated effects such as the shaking of a building can be notable. When <br />assessing annoyance from groundborne vibration, vibration is typically expressed as root mean <br />square (rms) velocity in units of decibels of 1 micro-inch per second. To distinguish these vibration <br />levels referenced in decibels from noise levels referenced in decibels, the unit is written as “VdB.” <br />In extreme cases, excessive groundborne vibration has the potential to cause structural damage to <br />buildings. Common sources of groundborne vibration include construction activities such as blasting, <br />pile driving and operating heavy earthmoving equipment. However, construction vibration impacts <br />on building structures are generally assessed in terms of peak particle velocity (PPV). For purposes of <br />this analysis, project related impacts are expressed in terms of PPV. <br />Short-term Construction Vibration Impacts <br />Of the variety of equipment that would be used during construction, small vibratory rollers would <br />produce the greatest groundborne vibration levels. Impact equipment such as pile drivers is not <br />expected to be used during construction of this project. Small vibratory rollers produce groundborne <br />vibration levels ranging up to 0.101 inch per second (in/sec) PPV at 25 feet from the operating <br />equipment. <br />The off-site structure nearest to the proposed construction areas where heavy construction <br />equipment would operate is the LPFD Fire Station No. 2 at 6300 Stoneridge Mall Road, east of the <br />project site. The façade of this structure would be located approximately 230 feet from the proposed <br />construction footprint where heavy equipment would operate. At this distance, groundborne <br />vibration levels would attenuate to 0.004 in/sec PPV from the operation of a small vibratory roller. <br />This is well below the industry standard vibration damage criteria of 0.2 in/sec PPV for this type of <br />structure, a building of non-engineered timber construction. <br /> <br />91 Federal Transit Administration (FTA). 2018. Transit Noise and Vibration Impact Assessment Manual. September.
The URL can be used to link to this page
Your browser does not support the video tag.