Laserfiche WebLink
"The real property described below is dedicated as an easement for public <br />purposes..." <br />Dedications for off-street parking held open to the public shall be granted in <br />conformance with Pleasanton Municipal Code §18.88.130. <br />Dedications in fee title shall only be granted upon approval by the City Engineer. <br />Consistent with California Government Code Section 66439(d)(2), the offer shall <br />include the statement, "The real property described below is dedicated in fee for <br />public purposes..." <br />(Address this condition prior to recordation of map or separate instrument title <br />documents granting rights to the City) <br />50. DATUM FOR VERTICAL CONTROL: Vertical control surveying for all improvements to <br />be constructed shall be based on the North American Vertical Datum of 1988 (NAVD 88). <br />Any benchmarks used that relied on the National Geodetic Vertical Datum of 1929 <br />(NGVD 29) shall be converted to NAVD 88 when presented on plans. The location of the <br />benchmark and source of data must also be disclosed on the plans. <br />(Address this condition prior to plan approval) <br />51. SURVEY MONUMENTS FOR HORIZONTAL CONTROL: Final maps shall include <br />sufficient durable survey monuments to allow the subdivision to be retraced in <br />conformance with Pleasanton Municipal Code §19.24.220. Setting of monuments shall <br />be in accordance with California Government Code §66495-66498. The surveyor shall <br />give notice to the City Engineer when final monuments have been set, and when <br />payment for said work has been received from the subdivider. <br />(Address this condition prior to acceptance of improvements) <br />52. EMERGENCY OVERLAND STORMWATER FLOW/SUMP PROPERTIES: All <br />properties shall be designed with an emergency overland flow path to direct storm runoff <br />to the nearest public street or open flood control facility in the event on-site pipes become <br />plugged. The flow path shall be lower than the finish floor elevation of all habitable <br />structures. The flow path cannot rely on neighboring properties unless a storm drain <br />easement across the neighbor is obtained. Sump properties must be designed to <br />discharge the 50 -year recurrence interval storm event through the pipe network before <br />habitable structures become inundated. <br />(Address this condition prior to plan approval) <br />53. EXISTING WATER METER REMOVALS: The removal of existing water meters that will be <br />permanently decommissioned shall be performed by City staff. The applicant shall contact the <br />City's Utility Billing Department at 925-931-5500 or osd@cityofpleasantonca.gov to initiate the <br />meter removal process. Any outstanding water consumption charges must be paid in full prior to <br />the meter removal as well as all fees associated with the disconnection. <br />(Address this condition prior to acceptance of improvement or issuance of an Occupancy Permit) <br />54. UTILITY ENCLOSURES: Proposed utility enclosures including vaults, meter boxes, splice boxes, <br />and pedestals shall be installed in the public right-of-way, in a public service easement (PSE), or <br />in a utility company specific easement. The locations for utility enclosures shall be considered in <br />the following order of preference: (1) PSE area behind public sidewalk; (2) parkstrip area <br />between the roadway curb & gutter and the sidewalk; (3) within the public sidewalk set flush to <br />grade; (4) within driveway approach areas set flush to the surface with traffic -rated lids. In no <br />case shall an above -ground pedestal or utility cabinet obstruct sight -line visibility for vehicle <br />drivers at intersections or driveways. Above -ground pedestals or utility cabinets are preferred <br />within the side -yard area of a corner residential lot rather than the front -yard. Deviations from this <br />standard must be approved by the City Engineer. <br />PUD -145 Planning Commission <br />Page 10 of 17 <br />