My WebLink
|
Help
|
About
|
Sign Out
03 ATTACHMENT 2
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2023
>
012623 SPECIAL
>
03 ATTACHMENT 2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2023 5:44:45 PM
Creation date
1/20/2023 5:17:43 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
1/26/2023
DESTRUCT DATE
15Y
Document Relationships
03
(Message)
Path:
\CITY CLERK\AGENDA PACKETS\2023\012623 SPECIAL
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
116
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Objective Design Standards for Multifamily Housing in R-M, C-C, and M-U Zoning Districts <br />City of Pleasanton - 25 - December 14, 2022January 5, 2023 <br />- DRAFT <br /> <br /> <br />B8B9. Utility and Service Area Location and Design <br />Utility and service functions should be completely contained and their impacts on development aesthetics <br />and pedestrian safety should be mitigated. Buildings and site plans should be organized to minimize the <br />impact of servicing functions and utilities on streets, open spaces, and paseos. <br /> <br /> <br /> <br />Design Standards <br />All Sites <br />B9.1 Utility and Service Areas shall be located to comply with all of the following standards: <br />a. Refuse and service areas shall be located at the rear of the building(s); <br />b. Exterior refuse areas shall be located outside of a 50 feet radius centered on the Primary <br />Building Entrance and shall be screened by opaque, roofed enclosures built of durable <br />materials and designed to harmonize with the proposed architecture; <br />c. Freestanding exterior enclosures shall be prohibited from encroachment into the Front Yard <br />Setback <br />d. Sites narrower than 100 feet in width shall locate all utilities and services at the location <br />farthest from the primary building entrance and any public street intersections. <br />B9.2 The following mechanical equipment, services, and utilities shall be screened with vision barriers <br />at a height of at least four feet; or 12 inches above the maximum height of any equipment <br />contained or equipment contained or stored within; whichever is greater. Vision barriers shall <br />include, but are not limited to, architectural elements such as louvered panels, durable walls or <br />gates, or landscape elements such as trees, shrubs, vines, and berms. <br />a. All utility equipment visible from, and located within 30 feet of a public right of way, unless <br />specifically prohibited by utility providers; including, but not limited to, transformers, pump <br />stations, backflow preventers, and valves. <br />b. Any mechanical equipment located at grade, exceeding two feet in height, and located within <br />15 feet of a public right of way, designated open space, pedestrian connection, or internal <br />street; including, but not limited to air conditioning condensers, ventilator fans, chillers, and <br />permanently installed generators. <br />
The URL can be used to link to this page
Your browser does not support the video tag.