My WebLink
|
Help
|
About
|
Sign Out
13
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2023
>
032123
>
13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/16/2023 9:01:39 AM
Creation date
3/16/2023 8:39:31 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
3/21/2023
DESTRUCT DATE
15Y
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
894
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
96. WATER FLOW AND CONTROL VALVES: All fire sprinkler system water flow and <br /> control valves shall be complete and serviceable prior to final inspection. Prior to the <br /> occupancy of a building having a fire alarm system, the Fire Department shall test and <br /> witness the operation of the fire alarm system. <br /> 97. ELECTRICAL CONDUIT: Electrical conduit shall be provided to each fire protection <br /> system control valve including all valve(s) at the water connections. The Livermore- <br /> Pleasanton Fire Department requires electronic supervision of all valves for automatic <br /> sprinkler systems and fire protection systems. <br /> 98. LISTED: All commercial, industrial, and multi-family residential occupancies shall have <br /> valve tamper and water flow connected to a listed Central Station Service in accordance <br /> with NFPA 72. Fire Department plan check includes specifications, monitoring, <br /> installation, and alarm company certificates. Fire alarm control panel and remote <br /> annunciation shall be at location(s) approved by the Fire Prevention Bureau. All systems <br /> shall be point identified by individual device and annunciated by device type and point. <br /> 99. HAZARDOUS MATERIALS DECLARATION: A Hazardous Materials Declaration shall <br /> be provided for this tenant and/or use. The form shall be signed by the owner/manager <br /> of company occupying the suite/space/building. No building permit shall be issued until <br /> the Hazardous Materials Declaration is provided. The form is available from the <br /> Livermore-Pleasanton Fire Department, Fire Prevention Bureau. <br /> 100. HAZARDOUS MATERIALS: Should any operation or business activity involve the use, <br /> storage or handling of hazardous materials, the firm shall be responsible for contacting <br /> the Livermore-Pleasanton Fire Department prior to commencing operations. Please <br /> contact the Hazardous Materials Coordinator at 925-454-2361. <br /> 101. FIRE HYDRANTS: Fire hydrants shall be installed at spacing not greater than <br /> approximately 300 feet in industrial and commercial developments. Fire hydrants shall <br /> be installed at spacing not greater than approximately 400 feet in residential <br /> developments. <br /> 102. FIRE LANE MARKING: On-site access ways, turn arounds, and internal drives shall be <br /> designated as fire lanes and identified as such by red curb striping and posted with signs <br /> at locations approve by the Fire Department. Signs shall be according to State standards <br /> and read "No Parking — Fire Lane" and must be shown on the plans. The red curb <br /> striping, sign location(s), and sign language shall be included in the building permit <br /> submittal for review and approval by the Livermore-Pleasanton Fire Department prior to <br /> building permit issuance. <br /> a. The following schedule for NO PARKING signs shall apply: <br /> Width Requirements <br /> Approximately 36 feet or greater No requirements <br /> Between approximately 28 and 36 feet Post one side <br /> Between approximately 20 and 28 feet Post both sides <br /> Less than approximately 20 feet Not permitted <br /> Cul-de-Sac Not permitted <br />
The URL can be used to link to this page
Your browser does not support the video tag.