My WebLink
|
Help
|
About
|
Sign Out
13
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2023
>
032123
>
13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/16/2023 9:01:39 AM
Creation date
3/16/2023 8:39:31 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
3/21/2023
DESTRUCT DATE
15Y
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
894
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ordinance No. <br /> Page 32 <br /> 103. EMERGENCY VEHICLE ACCESS ROADS: Access roads shall have approximately 13 <br /> feet and six inches unobstructed vertical clearance, approximately 20 feet of <br /> unobstructed width (approximately 26 feet where occupied building floors exceed <br /> approximately 30 feet height), and inside turning radius of approximately 31 feet and <br /> outside turning radius of approximately 51 feet. Unobstructed shall mean a clear travel <br /> way, excluding parking width, and designed for an emergency vehicle weight of <br /> approximately 70,000 pounds under all weather conditions. Unobstructed width shall not <br /> include the width of rolled curbs, sidewalks, or non-drivable surfaces. All exterior <br /> portions of buildings must be within approximately 200 feet of an access road. Yard and <br /> parking area may be able to be located farther than approximately 200 feet from access <br /> roads, depending on the specific use. <br /> 104. FIRE VEHICLE TURNAROUNDS: Where Fire Department vehicle access through or <br /> around a site involves changes in direction or curves, inside radius of 45 feet and <br /> outside radius of 55 feet shall be provided to facilitate fire truck turning radius for entry <br /> and exit from the site. Dead-end access ways and internal drives shall not exceed 300 <br /> feet in length and shall terminate in cul-de-sacs no less than 96 feet in diameter or <br /> hammer-head (tee). Standards and options are available through the Livermore- <br /> Pleasanton Fire Department, Fire Prevention Bureau. <br /> 105. PREMISES IDENTIFICATION: Address numbers shall be installed on the front or <br /> primary entrance for all buildings. Minimum building address character size shall be 12- <br /> inch high by 1-inch stroke. In all cases address numerals shall be of contrasting <br /> background and clearly visible in accordance with the Livermore-Pleasanton Fire <br /> Department Premises Identification Standards. This may warrant field verification and <br /> adjustments based upon topography, landscaping or other obstructions. <br /> 106. RESIDENTIAL— NEW CONSTRUCTION: The following items shall be provided prior to <br /> any construction above the foundation or slab. <br /> a. Emergency vehicle access shall be provided to the site (tract), including areas <br /> where construction is occurring. <br /> b. Designated construction material storage and construction worker parking shall <br /> not obstruct the emergency vehicle access route(s). <br /> C. On-site fire hydrants shall be in service. Fire hydrants shall be flushed and all <br /> valves open. <br /> 107. MULTI-FAMILY RESIDENTIAL— NEW CONSTRUCTION: Projects with more than 100 <br /> dwelling units shall be equipped throughout with two separate and approved fire <br /> apparatus access roads. <br /> 108. FINAL INSPECTION: Prior to request for final inspection, all access roads, on-site <br /> access and fire hydrants shall be provided. All fire hydrants shall be accepted, inspected <br /> and tested to applicable City Standards. <br />
The URL can be used to link to this page
Your browser does not support the video tag.