My WebLink
|
Help
|
About
|
Sign Out
04
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2023
>
090523 SPECIAL
>
04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2023 4:25:08 PM
Creation date
8/30/2023 4:02:42 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
9/5/2023
DESTRUCT DATE
15Y
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
168
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0602875 Pike Pole, 6', Pumper, Provided by <br />Fire Department, NFPA 2016 <br /> <br />6' PIKE POLE PROVIDED BY FIRE DEPARTMENT <br />NFPA 1901, 2016 edition, Section 5.9.4 requires one (1) 6' pike pole or plaster hook mounted in a <br />bracket fastened to the apparatus. <br />The pike pole is not on the apparatus as manufactured. The fire department will provide and <br />mount the pike pole. <br />The pike pole(s) will be a Duo-Safety 6' pike pole. <br />0004361 Tubes, Alum, Pike Pole Storage <br /> <br />PIKE POLE STORAGE <br />Aluminum tubing will be used for the storage of three (3) pike poles and will be located in ladder <br />storage compartment and in the hard suction hose compartment. If the head of a pike pole can <br />come in contact with a painted surface, a stainless steel scuffplate will be provided. <br />0532882 Label, "NO STEP" <br /> <br />WARNING LABEL(S) <br />There will be four (4) label(s), indicating "NO STEP", provided on top of each rear upper warning <br />beacon light located on the rear of the catwalks, and centered on top of the pump panel light <br />shields. <br />0692816 Label, Vinyl <br /> <br />SPECIAL LABEL <br />There will be one (1) special vinyl labels provided and installed Near the locking mechanism for <br />the swing out tool board in RS2. Place the label near the lock release tab. <br />The labels will be worded as follows, A white label with red letters "SWING OUT TOOLBOARD <br />LATCH LOCK" <br />0531401 Label, Special Information <br /> <br />LABEL <br />There will be one (1) label(s) provided upper portion of the rear wall of B1 with the following <br />information: "DO NOT DRILL/WATER TANK" AT LEAST .50" LETTERS IN RED . <br />0785102 Steps, Folding, Front of Body, Cargo <br />Bed Access, w/LED, Trident <br /> <br />FOLDING STEPS FRONT OF BODY <br />Folding steps will be provided full height on the left side and right side body compartments to <br />provide access to the cargo bed. Steps will be spaced evenly on the sales drawing. Actual <br />quantity may vary due to pump panel interferences but will meet the NFPA required maximum <br />stepping height. <br />The Trident steps will be bright finished, non-skid with a black tread coating on the stepping <br />surface. <br />The step will incorporate an LED light to illuminate the stepping surface. <br />The steps can be used as a hand hold with two openings wide enough for a gloved hand. <br />0592994 Steps, Folding, Rear of Body, w/LED, <br />Trident <br />REAR FOLDING STEPS <br />Bright finished, non-skid folding steps with a black tread coating on the stepping surface will be <br />provided at the rear. Each step will incorporate an LED light to illuminate the stepping surface. <br />The steps can be used as a hand hold with two openings wide enough for a gloved hand. <br />0650261 I Zone Bracket, Pair, Folding Style <br /> <br />I-ZONE BRACKETS <br />Two (2) flip-out I-Zone brackets will be provided and mounted at the rear of the apparatus, rear <br />bulkhead, match 26880 and 29597. The brackets will be designed with adequate reinforcement to <br />eliminate flexing of the body (oil canning). <br />0028046 Step, Spcl Width, Rear Of Body, 8", <br />Used w/Recessed Traffic Directing <br />Light <br />An 8.00" deep bright aluminum treadplate step will be provided at the rear of the body above the <br />rear compartment. The step will be sized to accommodate the mounting of a recessed traffic <br />directing light. The step will be located below the hosebed. <br />44717Bid #:
The URL can be used to link to this page
Your browser does not support the video tag.