Laserfiche WebLink
© 2024 - This original design(s) is the <br />exclusive property of FX SIGNS INC. <br />and is protected by federal copyrights <br />laws. Any reproduction or construction <br />of a sign similar to the one embodied <br />herein is expressly prohibited without <br />prior written consent of FX SIGNS INC. <br />OF11SHEET: <br />DATE:LANDLORD APPROVAL: <br />DATE:CLIENT APPROVAL: <br />REVISED BY: <br />DRAWN BY:SALES REP: <br />DRAWING INFORMATION: <br />CREATED DATE: <br />PROPERTY OWNER / MGT <br />CLIENT: <br />SITE LOCATION: <br />12155 MAGNOLIA AVE BLDG 11-A <br />RIVERSIDE, CA 92503 <br />(951) 689-0270 <br />FXCVI.COM <br />LIC# 1014540 <br />16 <br />SP <br />07 23 2024 <br />REVISION: R04 <br />SPFL <br />1427 R04 <br />June 19 2024 <br />PHILZ COFFEE <br />PROJECT MANAGER <br />Danny EstradaEmail: dannyestrada@philzcoffee.comPhone: (415) 359-6735 <br />Margaret TrujilloEmail: margarettrujillo@philzcoffee.comPhone: (650) 520-8357 <br />PHILZ COFFEE <br />1803 Santa Rita Rd, <br />Pleasanton, CA 94566 <br />DRIVE-THRU <br />DRIVE-THRU WALL SIGN <br />SCALE: ¾” = 1’-0” <br />SPECIFICATION TBD <br />SIGN AREA: 10.50 <br />Quantity: Two (2) Required <br />B2 <br />120 <br />Note: 1: All above is not in sign company scope <br />of work and must be in place prior to installation. <br />Circuit to be brought to job site by licensed electrician. <br />Note 2: Timers and/ or photocells for signs to be <br />furnished and installed by the customer’s electrician, <br />who should also ensure that the completed electrical <br />system is code compliant. <br />This sign is intended to be installed in accordance with requirements <br />of Article 600 of the National Electrical Code and/ or other applicable <br />local codes. This includes proper grounding and bonding of the sign. <br />The location of the disconnect switch after installation shall comply with <br />Article 600.6(A)(1) of the National Electrical Code. <br />Dedicated Amp Circuit at V <br />NOTE TO ALL CONTRACTORS <br />1 20 <br />UL MANUFACTOR #E357488 <br />ALL COMPONENTS TO BE APPROVED <br />PRIMARY ELECTRICAL TO SIGN LOCATIONS TO BE PROVIDED BY OTHERS WITH NO SHARED <br />NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR INSTALLATION. <br />ALL TRANSFORMERS SHALL BE, (GFI) GROUND FAULT-INTERRUPTED TRANSFORMERS. <br />ALL SIGNS HAVE - DEDICATED BRANCH CIRCUIT <br /> -THREE WIRES: LINE, NEUTRAL, & GROUND <br /> -WIRE SIZE: MINIMUM OF 12 GA. THIN COPPER WIRE <br />ALSO NOTE: GAUGE OF WIRE IS DETERMINED BY THE LENGTH OF RUN & AMPERAGE AS PER <br />NEC ARTICLE 300. <br />-GROUND WIRES MUST BE CONTINUOUS AND GO FROM THE SIGN TO THE PANEL BOARD <br />GROUND BUS. <br />-VOLTAGE SHOULD READ NO MORE THEN 3 VOLTS BETWEEN GROUND AND NEUTRAL. <br />-CONDUIT CAN NOT BE USED A GROUND PATH. <br />B1 <br />8 <br />½ <br />” <br />(D <br />) <br />1’ <br />- <br />6 <br />” <br />7’-0” <br />1 ISO VIEW <br />DRIVE-THRU WALL SIGN <br />SCALE: ¾” = 1’-0” <br />SPECIFICATION TBD <br />SIGN AREA: 5.83 <br />Quantity: One (1) Required <br />E <br />DRIVE-THRU7" <br />(D <br />) <br />1’ <br />- <br />2 <br />” <br />5’-0”