Laserfiche WebLink
© 2024 - This original design(s) is the <br />exclusive property of FX SIGNS INC. <br />and is protected by federal copyrights <br />laws. Any reproduction or construction <br />of a sign similar to the one embodied <br />herein is expressly prohibited without <br />prior written consent of FX SIGNS INC. <br />OF12SHEET: <br />DATE:LANDLORD APPROVAL: <br />DATE:CLIENT APPROVAL: <br />REVISED BY: <br />DRAWN BY:SALES REP: <br />DRAWING INFORMATION: <br />CREATED DATE: <br />PROPERTY OWNER / MGT <br />CLIENT: <br />SITE LOCATION: <br />12155 MAGNOLIA AVE BLDG 11-A <br />RIVERSIDE, CA 92503 <br />(951) 689-0270 <br />FXCVI.COM <br />LIC# 1014540 <br />16 <br />SP <br />07 23 2024 <br />REVISION: R04 <br />SPFL <br />1427 R04 <br />June 19 2024 <br />PHILZ COFFEE <br />PROJECT MANAGER <br />Danny EstradaEmail: dannyestrada@philzcoffee.comPhone: (415) 359-6735 <br />Margaret TrujilloEmail: margarettrujillo@philzcoffee.comPhone: (650) 520-8357 <br />PHILZ COFFEE <br />1803 Santa Rita Rd, <br />Pleasanton, CA 94566 <br />FRONT LIT CHANNEL LETTERS & DUAL LIT LOGO, WIREWAY MOUNTED <br />SCALE: ¾” = 1’-0” <br />MANUFACTURE AND INSTALL FACE LIT CHANNEL LETTERS & DUAL LIT CHANNEL FOR (STEAM & CUP) MOUNTED ONTO WIREWAY <br />SHOEBOX STYLE WIREWAY: <br />FACE: Shoebox Style .090 alum. welded to alum. return painted Matthews Paint MAP-LVS923 Black <br />BACK: Shoebox Style .090 alum. welded to alum. return painted Matthews Paint MAP-LVS923 Black <br />RETURN: 1” deep .063 alum. painted Matthews Paint MAP-LVS923 Black <br /> Secured w/ #8 x ½” pan head screws (1 every 10"-12" apart) <br />PHILZ COFFEE (FRONT LIT CHANNEL LETTERS): <br />FACES: 3/16” thick white acrylic plastic (no vinyl overlay) <br />BACKS: 3mm ACM Pre-coat White clinched to letter returns <br />TRIMCAPS: 1” thick White secured to alum. returns w/ #8 x ½" drilling screws <br />MOUNTING: Flush mounted to Shoebox Style alum. face, secured w/ #8" x ¾” hex head screws <br />RETURNS: 3” deep .040 alum. Pre-coat White <br />LIGHTING: 12V LEDs White Illumination | Remote power supplies <br />STEAM & CUP (DUAL LIT PAN-CHANNEL): <br />FACES: 3/16” thick white acrylic plastic with vinyl overlay (See colors schedule) <br />BACKS: 3/16” thick clear lexan for halo effect with diffuser apply to the back & clinched to letter returns <br />TRIMCAPS: 1” thick White for (STEAM) secured to alum. returns w/ #8 x ½" drilling screws <br /> 1” thick painted to match 3M 3630-84 Tangerine PMS 1575C for (CUP) secured to alum. returns w/ #8 x ½" drilling screws <br />RETURNS: 3” deep .040 alum. Pre-coat White for (STEAM) <br /> 3” deep .040 alum. painted to match 3M 3630-84 Tangerine PMS 1575C for (CUP) <br />SPACERS: To be mounted 2" away from Shoebox Style alum. face w/ #10-24 x 3" screws w/ spacers (4-6 spacers) & painted MAP-LVS923 Black <br />LIGHTING: 12V LEDs White Illumination | Remote power supplies <br />SIGN AREA: 23.43 <br />Quantity: One (1) Required <br />C <br />MATERIALS SCHEDULE <br />3/16" White AcrylicM-1 <br />3/16" Clear LexanM-2 <br />.090 AluminumM-4 <br />.063 AluminumM-5 <br />VINYL COLORS SECHEDULE <br />3M 3630-59 Dark BrownV-1 <br />3M 3630-84 TangerineV-2 <br />1" TrimcapM-3 <br />PAINT COLOR SECHEDULE <br />Matthews Paint MAP-LVS923 BlackP-1 <br />.040 Aluminum <br />DiffuserV-3 <br />M-6 <br />PMS 1575C TangerineP-2 <br />120 <br />Note: 1: All above is not in sign company scope <br />of work and must be in place prior to installation. <br />Circuit to be brought to job site by licensed electrician. <br />Note 2: Timers and/ or photocells for signs to be <br />furnished and installed by the customer’s electrician, <br />who should also ensure that the completed electrical <br />system is code compliant. <br />This sign is intended to be installed in accordance with requirements <br />of Article 600 of the National Electrical Code and/ or other applicable <br />local codes. This includes proper grounding and bonding of the sign. <br />The location of the disconnect switch after installation shall comply with <br />Article 600.6(A)(1) of the National Electrical Code. <br />Dedicated Amp Circuit at V <br />NOTE TO ALL CONTRACTORS <br />1 20 <br />UL MANUFACTOR #E357488 <br />ALL COMPONENTS TO BE APPROVED <br />PRIMARY ELECTRICAL TO SIGN LOCATIONS TO BE PROVIDED BY OTHERS WITH NO SHARED <br />NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR INSTALLATION. <br />ALL TRANSFORMERS SHALL BE, (GFI) GROUND FAULT-INTERRUPTED TRANSFORMERS. <br />ALL SIGNS HAVE - DEDICATED BRANCH CIRCUIT <br /> -THREE WIRES: LINE, NEUTRAL, & GROUND <br /> -WIRE SIZE: MINIMUM OF 12 GA. THIN COPPER WIRE <br />ALSO NOTE: GAUGE OF WIRE IS DETERMINED BY THE LENGTH OF RUN & AMPERAGE AS PER <br />NEC ARTICLE 300. <br />-GROUND WIRES MUST BE CONTINUOUS AND GO FROM THE SIGN TO THE PANEL BOARD <br />GROUND BUS. <br />-VOLTAGE SHOULD READ NO MORE THEN 3 VOLTS BETWEEN GROUND AND NEUTRAL. <br />-CONDUIT CAN NOT BE USED A GROUND PATH. <br />1’ <br />- <br />6 <br />” <br /> <br />( <br />P <br />) <br />2' <br />- <br />4 <br />" <br /> <br />W <br />I <br />R <br />E <br />W <br />A <br />Y <br />9’-8 ¾” <br />10’-0 3/8” WIREWAY <br />7" <br />ST <br />E <br />A <br />M <br />1' <br />- <br />3 <br /> <br />7 <br />/ <br />8 <br />" <br />CU <br />P