Laserfiche WebLink
(N) DAYCARE 5 <br />(E) BREAK RM <br />(E) MEN'S <br />RESTROOM <br />(E) WOMEN'S <br />RESTROOM <br />(E) OFFICE 1 <br />(E) LOBBY/ <br />RECEPTION (N) DAYCARE 1 <br />(E) HALLWAY D <br />(E) OFFICE 2(N) DAYCARE 4(E) OFFICE 3 <br />FIRE SPRINKLER <br />RM <br />ELECTRICAL RM <br />(E) RESTROOM LOBBY <br />(E) STORAGE <br />(N) DAYCARE 6 <br />(E) STAFF <br />HALLWAY E <br />(E) JANITORIAL <br />100101 <br />120 <br />118 <br />117 <br />116 <br />110 <br />109 <br />125 <br />111 <br />112 <br />107 106 105 <br />124 <br />(E) DAYCARE 2 <br />(N) DAYCARE 3 <br />104 <br />103 <br />102 <br />(N) LIBRARY <br />STACK AREA <br />128 <br />108 <br />119 <br />(N) HALLWAY B <br />122 <br />121 <br />123 <br />(E) STAFF <br />ALLEY <br />126 <br />(E) STUDENT <br />HANDWASH AREA <br />113 <br />(E) BOY'S <br />RESTROOM <br />115 <br />(E) GIRL'S <br />RESTROOM <br />114 <br />(N) PLAY AREA <br />(N) LIBRARY <br />READING AREA <br />127 <br />129 <br />(E) HALLWAY A <br />(E) HALLWAY C <br />1 <br />POWER PLAN <br />GENERAL NOTES: <br />KEYED POWER PLAN NOTES:# <br />1.VERIFY/COORDINATE EXACT LOCATION FOR ELECTRICAL EQUIPMENTS AND <br />PROVIDE/MAINTAIN MINIMUM CLEARANCE. [2022 CEC 110.26] <br />PANELPANEL <br />1 <br />XFMR <br />"TA" <br />MAIN SWITCHBOARD "MS" <br />"LB""LA" <br />NOT IN SCOPE OF WORK <br />NOT IN SCOPE OF WORK <br />NOT IN SCOPE OF WORK <br />NOT IN SCOPE OF WORK <br />(E) <br />(E) <br />(E)(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />(E) <br />LA-26 <br />LA-28 <br />LA-30 <br />1.ELECTRICAL EQUIPMENT SHALL BE LISTED BY U.L. OR CITY RECOGNIZED <br />ELECTRICAL TESTING LABORATORY OR APPROVED BY THE CITY <br />DEPARTMENT. <br />2.ALL ELECTRICAL WORK SHALL COMPLY WITH THE [2022 CEC]. <br />3.WIRE SIZE SHALL NOT BE LESS THAN CORRESPONDING CIRCUIT BREAKER <br />RATING AS REQUIRED. [2022 CEC TABLE 310.16] <br />4.CONDUIT SHALL BE SIZED IN ACCORDANCE WITH THE [2022 CEC ANNEX C]. <br />5.CONTRACTOR/ELECTRICIAN TO FIELD VERIFY ACTUAL SITE CONDITION <br />/EXACT SERVICE ENTRANCE AND SHALL NOTIFY EOR(S) ANY DISCREPANCY <br />WITH THE PLAN PRIOR TO BIDDING. <br />6.ALL ITEMS LABELED/IDENTIFIED AS EXISTING (IF ANY) ARE SUBJECT TO FIELD <br />VERIFICATION. VERIFY EXISTING CONDITION AND RE-USE. IF NOT EXISTING, <br />PROVIDE PER PLAN. <br />7.COORDINATE LOCATIONS/HEIGHTS OF RECEPTACLES FOR ELECTRICAL <br />DEVICES WITH ARCHITECT AND EQUIPMENT VENDER PRIOR TO ROUGH-IN. <br />8.ALL NEW ELECTRICAL EQUIPMENT (IF ANY) DIMENSIONS TO BE VERIFIED <br />WITH EQUIPMENT MANUFACTURER/VENDER PRIOR TO PURCHASE. <br />9.GFCI PROTECTION: ALL 125V THROUGH 250V RECEPTACLES SUPPLIED BY <br />1-PHASE BRANCH CIRCUITS, 50 AMPERES OR LESS, AND ALL RECEPTACLES <br />SUPPLIED BY 3-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO <br />GROUND, 100 AMPERES OR LESS, INSTALLED IN THE FOLLOWING LOCATIONS <br />SHALL HAVE GFCI PROTECTION FOR PERSONNEL. [2022 CEC 210.8(B)] <br />A.BATHROOMS <br />B.KITCHENS OR AREAS WITH A SINK AND PREM. PROVISION FOR COOKING <br />C.ROOFTOPS/OUTDOORS <br />D.SINKS - WITHIN 6FT FROM THE TOP INSIDE EDGE OF THE SINK <br />E.GARAGES, UNFINISHED AREAS OF BASEMENTS OR SIMILAR AREAS <br />10.FOR ALL PERMANENTLY CONNECTED APPLIANCES RATED OVER 300VA, THE <br />CIRCUIT BREAKER CAPABLE OF BEING LOCKED IN THE OPEN POSITION <br />SHALL BE PROVIDED UNLESS LOCATION OF THE BREAKER IS WITHIN THE <br />SIGHT OR SEPARATE DISCONNECTING MEANS IS PROVIDED. [2022 CEC <br />110.25, 422.31(B)] <br />11.TAMPER RESISTANT: ALL 15- AND 20-AMPERE, 125- AND 250-VOLT <br />NONLOCKING-TYPE RECEPTACLES IN THE FOLLOWING AREAS SHALL BE <br />LISTED TAMPER-RESISTANT RECEPTACLES [2022 CEC 406.12] <br />A.GUEST ROOMS OF HOTELS, MOTELS AND COMMON AREAS <br />B.CHILD CARE FACILITIES <br />C.PRESCHOOLS AND EDUCATION FACILITIES <br />D.BUSINESS OFFICES, CORRIDORS, WAITING ROOMS AND THE LIKE IN <br />CLINICS, MEDICAL AND DENTAL OFFICES, AND OUTPATIENT FACILITIES <br />E.PLACES OF AWAITING TRANSPORTATION, GYMNASIUMS, SKATING RINKS, <br />AND AUDITORIUMS <br />F.DORMITORY UNITS <br />G.ASSISTED LIVING FACILITIES <br />NOT IN SCOPE OF WORK <br />NOT IN SCOPE OF WORK <br />TO EXISTING CKTS <br />TO EXISTING CKTS <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />SHEET TITLE: <br />DATE: SCALE: <br />11/14/2023 <br />PLOT DATE: 5/13/2024 12:05:03 PM <br />CD <br />I <br /> <br />Ci <br />r <br />c <br />a <br /> <br />D <br />o <br />m <br />i <br />n <br />i <br /> <br />I <br />n <br />t <br />e <br />r <br />n <br />a <br />t <br />i <br />o <br />n <br />a <br />l <br />, <br /> <br />I <br />n <br />c <br />. <br />En <br />g <br />i <br />n <br />e <br />e <br />r <br />i <br />n <br />g <br /> <br />- <br /> <br />C <br />o <br />n <br />s <br />u <br />l <br />t <br />i <br />n <br />g <br />98 <br />9 <br />0 <br /> <br />R <br />e <br />s <br />e <br />a <br />r <br />c <br />h <br /> <br />D <br />r <br />. <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />1 <br />0 <br />0 <br />, <br /> <br />I <br />r <br />v <br />i <br />n <br />e <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />1 <br />8 <br />Ph <br />o <br />n <br />e <br /> <br />( <br />9 <br />4 <br />9 <br />) <br /> <br />5 <br />3 <br />3 <br />- <br />4 <br />1 <br />1 <br />7 <br /> <br />| <br /> <br />d <br />k <br />a <br />n <br />g <br />@ <br />c <br />d <br />i <br />e <br />n <br />g <br />. <br />c <br />o <br />m <br />66 <br />6 <br />3 <br /> <br />O <br />W <br />E <br />N <br />S <br /> <br />D <br />R <br />, <br />PL <br />E <br />A <br />S <br />A <br />N <br />T <br />O <br />N <br />, <br /> <br />C <br />A <br /> <br />9 <br />4 <br />5 <br />8 <br />8 <br />DRAWN: CHECKED: <br />AC <br />A <br />D <br />E <br />M <br />I <br />C <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br />VO <br />L <br />I <br />T <br />A <br />T <br />I <br />O <br />N <br /> <br />C <br />O <br />R <br />P <br />. <br /> <br />D <br />A <br />Y <br />C <br />A <br />R <br />E <br />E200 <br />1/8" = 1'-0" <br />POWER PLAN <br />J.L.K.T