Laserfiche WebLink
Tract 8724, 0 Vineyard Avenue Planning Commission <br />Page 9 of 11 <br /> <br /> <br /> <br />instructions and maintenance and replacement schedule for the HVAC system <br />and filters, and that manual shall be distributed to owners. <br />Project applicants shall retain a qualified air quality consultant to prepare a health risk <br />assessment (HRA) in accordance with BAAQMD requirements to determine the <br />exposure of project residents/occupants/users to air pollutants prior to issuance of a <br />grading permit, or issuance of a building permit, whichever is sooner. The HRA shall be <br />submitted to the Community Development Department for review and approval. For <br />individual projects, the HRA shall be completed and identified recommendations in <br />order to reduce exposure to TACs below BAAQMD thresholds of significance, if any, in <br />the HRA shall be incorporated into design and construction documents as Conditions of <br />Approval prior to issuance of grading or building permit, whichever is sooner. <br />Outdoor Air Quality–Individual and common exterior open space, including playgrounds, <br />patios, and decks, shall either be shielded from the source of air pollution by buildings <br />or otherwise buffered to further reduce air pollution for project occupants. <br />• MM GEO-6: A professional paleontologist, approved by the City of Pleasanton, shall <br />conduct a site-specific paleontological resources survey on the potential sites for <br />rezoning. If any of the potential sites for rezoning are found to be underlain by older <br />Quaternary deposits, or any other soil with the potential to contain vertebrate fossils due <br />to their high paleontological sensitivity for significant resources, applicants, owner s <br />and/or sponsors of all future development or construction projects shall be required to <br />perform or provide paleontological monitoring, if recommended by the qualified <br />paleontologist. Should significant paleontological resources (e.g., bones, teeth, well- <br />preserved plant elements) be unearthed by a future project construction crew, project <br />activities shall be diverted at least 15 feet from the discovered paleontological resources <br />until a professional paleontologist has assessed such discovered resources to <br />determine whether they are significant, and significant resources shall be salvaged in a <br />timely manner. The applicant/owner/sponsor of said project shall be responsible for <br />diverting project work and providing the assessment including retaining a professional <br />paleontologist for such purpose. Collected fossils shall be deposited by the <br />applicant/owner/sponsor in an appropriate repository where the collection shall be <br />properly curated and made available for future research (e.g., University of California <br />Museum of Paleontology (UCMP), California Academy of Sciences). <br />• MM NOI-1: Prior to issuance of building permits for a project, for any development <br />project on potential sites for housing that would include any noise-producing mechanical <br />systems located within 25 feet of a property line, the project applicant shall retain a <br />Noise Specialist to conduct a site-specific project-level noise analysis to evaluate <br />compliance with Section 9.04.030 of the Municipal Code, which prohibits noise levels in <br />excess of 60 A-weighted decibel (dBA) at any point outside the property plane, as <br />defined in Section 9.04.020 of the Municipal Code as “a vertical plane including the <br />property line which determines the property boundaries in space”. If the analysis <br />identifies that proposed mechanical system operations could result in an exceedance of <br />this noise performance standard, then specific measures to attenuate the noise impact <br />shall be outlined in the analysis. The analysis shall be submitted to the City’s Building & <br />Safety Division for review and approval prior to issuance of building permits. The final <br />noise-reduction measures shall be included on all final construction and building