My WebLink
|
Help
|
About
|
Sign Out
ST. FRANCIS ELECTRIC (#2025586)
City of Pleasanton
>
CITY CLERK
>
CONTRACTS
>
S
>
ST. FRANCIS ELECTRIC (#2025586)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2026 4:08:49 PM
Creation date
8/18/2025 4:05:19 PM
Metadata
Fields
Template:
CONTRACTS
Description Type
Maintenance Services
Contract Type
New
NAME
ST. FRANCIS ELECTRIC, LLC
Contract Record Series
704-05
Munis Contract #
2025586
Contract Expiration
6/30/2027
NOTES
CONTRACTOR PROVIDING TRAFFIC SIGNAL MAINTENANCE SERVICES
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Traffic Signal Maintenance Contract Contract No.______ <br />Scope of Work Page 17 <br /> <br /> <br />Section 12 PREVENTATIVE MAINTENANCE SCHEDULE <br />The City requires that the Contractor will perform preventative maintenance on all signal equipment. <br />A traffic signal includes, but is not limited to: traffic signal controller and cabinet and all appurtenant <br />equipment, service cabinet, flashing beacons related to traffic signal operations (i.e. advanced <br />warning beacons), pedestrian and vehicle signals, detector systems, video detection camera systems, <br />CCTV camera systems, wireless vehicle detection system, interconnect cable (copper and fiber <br />optic), wireless communications equipment, traffic signal communications equipment, emergency <br />vehicle preemption system, uninterrupted power supply system, intersection safety lighting, <br />internally illuminated street name signs, and radar speed signs related to traffic signal operations. <br /> <br />The Contractor shall use a Windows-based computerized maintenance and inventory management <br />system to record all work done as outlined in the Scope of Work. The Preventative Maintenance <br />database shall be continually updated. The City shall have access to the database via the internet as <br />well as an updated hard copy of the database that shall be furnished to the City on a monthly basis. <br />All records shall be updated in real time by the contractor via Smartphone or similar device. <br /> <br />Upon completion of each Preventative Maintenance inspection detailed in this schedule, the <br />contractor shall supply a computerized report to the City Traffic Engineering Division itemizing <br />each check performed and the result of that check. A separate report shall be generated for the <br />monthly, quarterly, and annual, even when all of these checks occur in the same month. <br /> <br />The Contractor shall also provide a computerized monthly report to the City Traffic Engineering <br />Division of the Community Development Department by the fifteenth day of each month that <br />summarizes the pending repair work needed at each intersection. This report shall be broken down <br />by intersection and be separate from the Preventative Maintenance Report. This may be provided by <br />hard copy or by email on the 15th day of each month. <br /> <br />The contractor shall perform the following Monthly Preventative Maintenance inspections and <br />corrective work every month. <br /> <br />1. Controller Cabinet <br />• Test and Check ground fault receptacle <br />• Observe the general appearance of the cabinet, noting any rust or other signs of <br />deterioration and complete/recommend repair work if needed <br />• Inspect door gasket condition and replace if necessary <br />• Inspect door lock operation and replace if necessary <br />• Operate and inspect ventilation fan and cabinet light (where applicable) <br />• Inspect for pests in cabinet and take corrective action if needed <br />• Visually inspect all relays, photocells, cabinet locks, cabinet fans, switches and make <br />routine adjustments and repairs as necessary <br />• Move the fan thermostat setting and determine if fan is operable. Return thermostat to <br />Docusign Envelope ID: 3B82A602-152E-44CD-836A-6603E8712601
The URL can be used to link to this page
Your browser does not support the video tag.