My WebLink
|
Help
|
About
|
Sign Out
CITY COUNCIL REGULAR AGENDA PACKET
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2025
>
100725 REGULAR
>
CITY COUNCIL REGULAR AGENDA PACKET
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2025 3:27:07 PM
Creation date
10/10/2025 3:21:29 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
10/7/2025
DESTRUCT DATE
15Y
DOCUMENT NO
CITY COUNCIL REGULAR MEETING AGENDA PACKET 10/7/25
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
376
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Attachment 1 Exhibit B <br />Page 11 of 64 <br />provided further that such suspension or abandonment has not exceeded one year. In order to renew <br />action on a permit after expiration, the permittee shall pay a new full permit fee. <br /> <br />Any permittee holding an unexpired permit may apply for an extension of the time within which work <br />may commence under that permit when the permittee is unable to commence work within the time <br />required by this section for good and satisfactory reasons. The Building and Safety Official may extend <br />the time for action by the permittee for a period not exceeding 180 days on written request by the <br />permittee showing that circumstances beyond the control of the permittee have prevented action from <br />being taken. <br /> <br />To conform with requirements in SB721, Section 20.04.350 is amended to read as follows: <br /> <br />20.04.350 Required building inspections. <br /> <br />Reinforcing steel or structural framework of any part of a building or structure or any plumbing, <br />mechanical or electrical components shall not be covered or concealed without first obtaining the <br />approval of the Building and Safety Official. Protection of joints and penetrations in fire- resistive <br />assemblies shall not be concealed from view until inspected and approved. <br /> <br />The Building and Safety Official shall require notification from the permit holder in order to make the <br />following inspections: <br /> <br />1. Foundation Inspection. Footing and foundation inspections shall be made after excavations for <br />footings are complete and any required reinforcing steel is in place. Plumbing, mechanical or <br />electrical components are required to be in place. For concrete foundations, required forms shall be <br />in place prior to inspection. The foundation inspection shall include excavations for thickened slabs <br />intended for the support of bearing walls, partitions, structural supports, or equipment. Materials <br />for the foundation shall be on the job, except where concrete is ready mixed in accordance with <br />ASTM C 94, the concrete need not be on the job. <br /> <br />2. Under-slab and Under-floor Inspection. Concrete slab and under-floor inspections shall be made <br />after in-slab or under-floor reinforcing steel and building service equipment, conduit, wiring, <br />ducting, piping accessories or other ancillary equipment items are in place, but before any concrete <br />is placed, or insulation and/or floor sheathing is installed, including the subfloor. <br /> <br />3. Floodplain Inspection, in designated flood hazard areas. Upon placement of the lowest floor and <br />prior to further vertical construction, a registered design professional shall prepare and submit <br />documentation to the Building and Safety Official of the elevation of the lowest floor, including <br />basement, as required in Section 1612.4 of the California Building Code, or for one-and two-family <br />dwellings, Section R306 of the California Residential Code. <br /> <br />4. Shear and Roof Inspection. A lateral bracing, roof framing and sheathing inspection shall be made <br />before any weather protection covering or roofing material is installed on the walls or roof of any <br />building. <br /> <br />5. Plumbing, Mechanical, Gas and Electrical Inspection. Rough inspection of plumbing, mechanical, <br />gas and electrical systems shall be made prior to covering or concealment, before fixtures or <br />appliances are set or installed, and prior to framing inspection. <br /> <br />Page 22 of 376
The URL can be used to link to this page
Your browser does not support the video tag.