Attachment 1 Exhibit B <br />Page 38 of 64 <br /> <br />6004.2.1.4 Quantities not exceeding minimum threshold quantity per control area. The indoor <br />storage or use of highly toxic, toxic and moderately toxic gases in amounts not exceeding the <br />minimum threshold quantity per control area set forth in Table 6004.1 shall be in accordance with <br />Sections 6001, and 6004.1 and Chapter 50. <br /> <br />20.24.500 CFC Section 6004.2.1.5 amended – Quantities exceeding minimum threshold quantity per <br />control area. <br /> <br />Section 6004.2.1 is added to read: <br /> <br />6004.2.1.5 Quantities exceeding the minimum threshold quantity per control area. The indoor <br />storage or use of highly toxic, toxic and moderately gases in amounts exceeding the minimum <br />threshold quantity per control area set forth in Table 6004.1 shall be in accordance with Sections <br />6001, 6004.1, 6004.2 and Chapter 50. <br /> <br />20.24.510 CFC Section 6004.2.2 amended – General indoor requirements. <br /> <br />Section 6004.2.2 is hereby amended to read: <br /> <br />6004.2.2 General indoor requirements. The general requirements applicable to the indoor storage <br />and use of highly toxic, toxic and moderately toxic compressed gases shall be in accordance with <br />Sections 6004.2.2.1 through 6004.2.2.10.3. <br /> <br />Moderately toxic gases shall not be considered as toxic gases for maximum allowable quantities <br />determinations under Table 5003.1.1(2). <br /> <br />20.24.520 CFC Section 6004.2.2.5 amended – Piping and controls -stationary tanks, Item 1. <br /> <br />The Exception in Section 6004.2.2.5 Piping and controls – stationary tanks, Item 1 exception deleted. <br /> <br />20.24.530 CFC Section 6004.2.2.7 amended – Treatment systems. <br /> <br />Exception 2 in Section 6004.2.2.7 Treatment systems is deleted. <br /> <br />20.24.540 CFC Section 6004.2.2.10.1 amended – Alarms. <br /> <br /> The Exception in Section 6004.2.2.10.1 Alarms is deleted. <br /> <br />20.24.550 CFC Section 6004.3 amended – Outdoor storage and use. <br /> <br />Section 6004.3 is hereby amended to read: <br /> <br />6004.3 Outdoor storage and use. The outdoor storage or use of highly toxic, toxic and moderately <br />toxic gases shall be in accordance with Sections 6004.3.1 through 6004.3.4. The minimum threshold <br />quantity for highly toxic, toxic and moderately toxic gases for outdoor storage and use are set forth in <br />Table 6004.1. <br /> <br />20.24.560 CFC Section 6004.3.1 amended – Applicability. <br /> <br />Section 6004.3.1 is hereby amended to read: <br />Page 49 of 376