Laserfiche WebLink
<br />Page 28 <br /> <br />94. FRONTAGE SIDEWALK WIDENING. The public sidewalk that fronts the property <br />along the south side of Black Avenue contains segments that have been <br />lifted/damaged by the growth of street trees. Said damage shall be addressed by <br />replacement of defective sidewalk in accordance with Pleasanton standards as part of <br />the development. The horizontal clearance around each street tree shall be sufficient <br />to allow unobstructed access by the disabled. If any portion of the sidewalk extends <br />beyond the public right-of-way line, a Public Access Easement shall be granted to the <br />City across that portion. (Address this condition prior to plan approval). <br /> <br />95. BACKFLOW PREVENTION ASSEMBLIES: Backflow preventer assemblies shall be <br />designed and installed in accordance with current City Standard Drawings 704, 705, <br />706; Pleasanton Municipal Code Chapter 14.16, State Health and Safety Code; State <br />Water Resources Control Board adopted Cross-Connection Control Policy Handbook <br />(CCCPH); and as required by the Public Works Department. Backflow Preventers <br />(BFP) shall be selected from the latest “List of Approved Backflow Prevention <br />Assemblies” available from the Foundation for Cross-Connection Control and <br />Hydraulic Research at the University of Southern California. All backflow preventer <br />assemblies shall be tested and certified by a City approved tester with the certification <br />submitted to the City. Testing will be performed at the time City water is turned on to <br />the site. If an existing backflow preventer is on the site, it shall be tested and certified <br />by a City-approved tester with the certification submitted to the City before project <br />water is drawn through it. An all-weather cover shall be placed over all backflow <br />prevention assemblies 4 inches and smaller, and follow City Standard Specification <br />19-02N for backflow enclosure requirements. (Address this condition prior to plan <br />approval). <br /> <br />96. DRIVEWAY APPROACHES. The existing driveway approaches that formerly served <br />the AT&T use, shall be removed and replaced with standard public sidewalk according <br />to City of Pleasanton Standard Drawing 103. The related red-painted curbs shall also <br />be removed. The proposed driveway approach shall be constructed according to <br />Standard Drawing 106 with an accessible pedestrian path of travel at the back. If any <br />portion of the pedestrian path extends beyond the public right-of-way line, a Public <br />Access Easement shall be granted to the City across that portion. (Address this <br />condition prior to plan approval). <br /> <br />97. LIGHTING AND PHOTOMETRICS. Site lighting in private street and parking areas <br />shall be designed to incorporate 50 percent dimming controlled by occupancy sensor <br />between the hours of 11:00 PM and 7:00 AM. (Address this condition prior to plan <br />approval). <br /> <br /> <br /> <br />