My WebLink
|
Help
|
About
|
Sign Out
PC-2025-16
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
2020 - PRESENT
>
2025
>
PC-2025-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2025 10:30:44 AM
Creation date
12/23/2025 10:28:35 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
7/23/2025
DESTRUCT DATE
PERMANENT
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
277
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ENGEO <br /> INCORPORATED <br /> <br /> <br />5150.100.101 <br />May 2, 2008 Page 19 <br />7.2 FOOTING DIMENSIONS AND ALLOWABLE BEARING CAPACITY <br /> <br />Provide minimum footing dimensions as follows: <br /> <br />Table 4 <br />Minimum Footing Dimensions <br /> <br />Footing Type <br />*Minimum <br />Depth (in.) <br /> <br />Minimum Width (in.) <br />Continuous 18 18 <br />Isolated 18 18 <br />*below lowest adjacent pad grade <br /> <br />Minimum footing depths shown above are taken from lowest adjacent pad grade. The cold joint <br />between the exterior footing and slab-on-grade should be located at least 4 inches above adjacent <br />exterior grade. <br /> <br />Design foundations recommended above for a maximum allowable bearing pressure of <br />3,000 pounds per square foot (psf) for dead plus live loads. Increase this bearing capacity by <br />one-third for the short-term effects of wind or seismic loading <br /> <br />The maximum allowable bearing pressure is a net value; the weight of the footing may be <br />neglected for design purposes. All footings located adjacent to utility trenches should have their <br />bearing surfaces below an imaginary 1:1 (horizontal:vertical) plane projected upward from the <br />bottom edge of the trench to the footing. <br /> <br />7.3 WATERSTOP <br /> <br />If a two-pour system is used for footings and slab, the cold joint between the exterior footing and <br />slab-on-grade should be located at least 4 inches above adjacent finish exterior grade. If this is <br />not done, then we recommend the addition of a waterstop between the two pours to reduce <br />moisture penetration through the cold joint and migration under the slab. Use of a monolithic <br />pour would eliminate the need for the waterstop.
The URL can be used to link to this page
Your browser does not support the video tag.