My WebLink
|
Help
|
About
|
Sign Out
PC-2025-16
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
2020 - PRESENT
>
2025
>
PC-2025-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2025 10:30:44 AM
Creation date
12/23/2025 10:28:35 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
7/23/2025
DESTRUCT DATE
PERMANENT
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
277
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Peer Review of Geotechnical and Geologic Hazard Investigations BSK Project G2300051 <br />11991 Dublin Canyon Road (Hana Japan) September 6, 2024 <br />Pleasanton, California Page 3 <br /> <br /> <br />During our review of the subject documents, we have identified items that require additional information <br />or clarification. Items requiring additional information or clarification are listed below. <br /> <br />1. CBC Update Letter: The letter characterizes the Site as Site Class D whereas the Geotechnical <br />Report characterizes the Site as Site Class C. Some of the values provided in Table 1 appear to be <br />consistent with a Site Class C, while others are consistent with Site Class D. The discrepancy <br />between Site Class characterizations and their associated seismic design values should be <br />clarified. In addition, consideration should be given to providing an appropriate justification for <br />the Site Class selected. <br />2. Fault Exploration Report, Conclusions and Recommendations: <br />a. Based on the mapped fault location by Hart (1981) and others, and the lack of existing <br />subsurface information in this area of the Site within the Alquist-Priolo Earthquake Fault <br />Zone (AP Zone) for the Calaveras Fault, we do not consider a setback distance of 25 feet <br />for structures intended for human occupancy to be adequate based on the amount of <br />subsurface uncertainty at the southwest edge of the Site. The consultant should provide <br />reasoning why a smaller setback distance was recommended from a potential fault trace <br />in an area with limited subsurface information. <br />b. Clearer recommendations should be provided for addressing the potential for secondary <br />ground deformations. <br />c. Please define the term “a few inches” when discussing secondary ground deformations. <br />Perhaps provide a range of possible values. <br />3. Fault Exploration Report, Figure A1 (Trench Logs T-1 through T-3): At approximately Station 0+52 <br />in exploratory trench ET-1, apparent bedding with a strike of N15°W and dip of 65°W was <br />encountered between sandstone, siltstone, and conglomerate. This apparent bedding attitude is <br />not consistent with the apparent bedding documented within the exploratory trenches at the site <br />(majority are striking further west and dipping to the east). Given the strike of the Calaveras Fault <br />at the Site and the inconsistency with local bedding noted in the other exploratory trenches, the <br />consultant should provide a discussion and reasoning as to why this potentially anomalous <br />bedding attitude is not considered potentially fault-related. <br />4. Geotechnical Report, Section 1 (Introduction): This section of the Geotechnical Report states that <br />finished floor elevations are anticipated to be 385.5 feet above mean sea level (MSL). However, <br />according to Sheets C3 through C5 of the project plans, the finished floor is shown as 382 feet <br />MSL. ENGEO should evaluate whether this is a concern or not given that perched groundwater <br />was encountered as shallow as 379.5 feet MSL according to the Geotechnical Report. <br />5. Geotechnical Report, Section 3 (Project Description): This section of the Geotechnical Report <br />states that site improvement will include cuts up to 16 feet. However, Sheet C4 of the Project <br />Plans shows greater than 20 feet of cuts along the east edge of the planned building footprint. <br />ENGEO should evaluate whether this is a concern or not. <br />6. Geotechnical Report, Section 4.3 (Subsurface Conditions): Consideration should be given to <br />presenting the previous boring logs by Hydro-Geo Consulting and Harding Lawson Associates in <br />an Appendix of the Geotechnical Report. The locations of these boring logs are shown on Figure <br />2 of the Geotechnical Report.
The URL can be used to link to this page
Your browser does not support the video tag.