Laserfiche WebLink
<br /> <br /> <br />City of Pleasanton, CA (0012108.00) 3-8 Woodard & Curran, Inc. <br />Pleasanton Long-Term Sewer CIP October 6, 2025 <br />Recommendations TM or pipes inspected in the near-term as part of the priority A <br />recommendations. <br />• Sewer Siphon Replacement and Large Diameter Trunk Rehabilitation – This line item includes <br />funding for possible rehabilitation or replacement of sewer siphon replacement or trunk sewers <br />based on the findings of the inspections included in priority A. These costs will not be sufficient to <br />rehabilitate or replace multiple siphons and/or trunk sewers, and it is recommended that this line <br />item be revised following the results of the inspections and desktop analyses. <br />3.5 Priority C Projects <br />Priority C projects include additional rehabilitation and replacement recommendations for pipes in poor <br />condition that have not yet been CCTV’d. Pipes will be selected based on their inspected condition as <br />identified as part of future condition assessment effort. These projects are more programmatic in nature <br />and represent the required investment to maintain the sewer network. Also included in this priority is the <br />reinspection of sewer siphons, trunk sewers, and gravity mains and follow up condition assessment work. It <br />is critical that the City continues to identify assets in poor condition as the system ages and react proactively <br />to maintain a high level of service to the public. <br />Page 234 of 323