Laserfiche WebLink
<br />6 <br />d. Construction Fencing Plan, including plan and profile. C) A Structural Design Plan shall include: a. Proposed building footprint(s), heights, vertical and lateral force resisting systems, and foundation types. b. Shoring Plan/Excavation support system including design assumptions. c. Ground Water Management Plan. d. Vibration, Settlement, and/or other Displacement Monitoring Plan. e. A list of building codes with which the design will comply. D) Safety and Security Plan: a. Identify operable windows. b. Identify balconies & rooftop outdoor areas. c. Identify plan for vehicular access protection to station entrances and ventilation structures. d. Identify access for Fire (Fire Access Map to include Development Building accesses) and Police Services including dedicated parking at all BART station access points. <br />Page 316 of 399