Laserfiche WebLink
5 <br />ROOF BATT INSULATION SEE CBC <br />DRAWINGS. <br />METAL LINER PANEL, SEE CBC <br />DRAWINGS. <br />DOWNSPOUT AND GUTTER, SEE <br />CBC DRAWINGS. <br />METAL PANEL WALL SYSTEM <br />6 <br />METAL PANEL ROOF SYSTEM, <br />SEE CBC DRAWINGS. <br />Z-PURLIN, SEE CBC DRAWINGS. <br />STRUCTURAL <br />TAPERED STEEL <br />COLUMN BEYOND, <br />SEE CBC DRAWINGS. <br />STRUCTURAL TAPERED STEEL <br />RAFTER BEYOND, <br />SEE CBC DRAWINGS. <br />1' - 2" <br />2 <br />BREAK METAL SOLAR SHADE <br />1 <br />24" <br />4" <br />METAL PANEL WALL SYSTEM <br />SEE CBC DRAWINGS. <br />1' - 2" <br />SEALENT <br />BASE TRIM FLASHING. <br />1/4" METAL PLATE <br />2" X 6" CENTER <br />GLAZED THERMALLY <br />BROKEN STOREFRONT <br />SYSTEM <br />STUD METAL FRAMING, SEE <br />STRUCTURAL DRAWINGS. <br />FINISH GRADE <br />0" <br />CONCRETE PERIMETER <br />GRADE BEAM, SEE <br />STRUCTURAL <br />DRAWINGS. <br />12" CONCRETE CURB AT <br />EXTERIOR WALLS, TYP. <br />SEE STRUCTURAL <br />DRAWINGS <br />EXTERIOR HARDSCAPE <br />IMPROVEMENTS, <br />SEE CIVIL DRAWINGS. <br />SLAB ON GRADE, SEE <br />SRUCTURAL <br />DRAWINNGS. <br />16" <br />36 <br />" <br />12 <br />" <br />VARIES <br />METAL BASE MEMBER <br />SEE CBC DRAWINGS. <br />METAL PANEL WALL, SEE <br />CBC DRAWINGS. <br />SEALENT <br />BASE TRIM FLASHING, <br />SEE CBC DRAWINGS. <br />STRUCTURAL STEEL <br />TAPERED BEAM, SEE CBC <br />DRAWINGS. <br />METAL PANEL ROOF <br />SYSTEM BEYOND <br />METAL PANEL ROOF <br />SYSTEM. SEE CBC <br />DRAWINGS. <br />METAL ROOF EDGE <br />FLASHING, TYP <br />B <br />METAL PANEL ROOF SYSTEM, <br />SEE CBC DRAWINGS. <br />STRUCTURAL STEEL TAPERED <br />BEAM SSD <br />ROOF BATT INSULATION, SEE <br />CBC DRAWINGS. <br />METAL LINER PANEL, SEE CBC <br />DRAWINGS. <br />6" METAL ROOF FLASHING <br />OVER WALL PANEL, TYP <br />6" <br />METAL PANEL WALL SYSTEM <br />A <br />1' - 6" <br />ISSUANCE & REVISIONS <br />All drawings and written material appearing herein constitute the <br />original and unpublished work of the architect and the same may <br />not be duplicated, used, or disclosed without the written consent of <br />the architect © Field Paoli <br />SHEET NUMBER: <br />JOB NO. <br />CHECKED BY <br />DRAWN BY <br />NOT FOR CONSTRUCTION <br />3/ <br />1 <br />4 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />1 <br />1 <br />: <br />4 <br />2 <br />: <br />5 <br />6 <br /> <br />A <br />M <br />A-8.0 <br />CONSTRUCTION DOCUMENTS <br />2348 <br />RYB / AFC <br />WL / CS <br />SCHEMATIC DETAILS <br />NO. DESCRIPTION DATE <br />DESIGN REVIEW SUBMITTAL 07.17.2024 <br />1 DESIGN REVIEW RESUBMITTAL 09.13.2024 <br />2 DESIGN REVIEW RESUBMITTAL 02.07.2025 <br />1" = 1'-0"A-8.0 <br />5 DETAIL - ROOF GUTTER <br />1 1/2" = 1'-0"A-8.0 <br />2 DETAIL @ WINDOW SOLAR SHADE <br />1" = 1'-0"A-8.0 <br />1 DETAIL @ PERIMETER GRADE BEAM CURB <br />1" = 1'-0"A-8.0 <br />3 DETAIL - ROOF EDGE @ SOUTH <br />1" = 1'-0"A-8.0 <br />4 DETAIL - ROOF FLASHING @ NORTH WALL