My WebLink
|
Help
|
About
|
Sign Out
Planning Commission Meeting Agenda Packet (2)
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
AGENDA PACKETS
>
2020 - PRESENT
>
2025
>
05-14
>
Planning Commission Meeting Agenda Packet (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/30/2025 3:16:17 PM
Creation date
12/30/2025 3:10:56 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1 <br />10 <br />2 <br />3 6 <br />7 <br />8 <br />8 <br />9 <br />9 <br />11 <br />PB <br />PULL BOX FOR EV CAPABLE PARKING <br />DUAL HEAD <br />PB <br />DUAL HEAD <br />PULL BOX FOR EV CAPABLE PARKING <br />SIGNAGE <br />SIGNAGE <br />PB PULL BOX FOR AUTOMATED GATE <br />523 <br />B <br />C <br />F <br />H <br />D <br />G <br />6 <br />A <br />1 4 <br />E <br />4 <br />PA <br />N <br />E <br />L <br /> <br />D <br />PA <br />N <br />E <br />L <br /> <br />C <br />PA <br />N <br />E <br />L <br /> <br />B <br />PA <br />N <br />E <br />L <br /> <br />A <br />B-7(9,11) <br />B-1(3,5) <br />MPOE <br />GENERATOR <br />CONNECT <br />SECTION <br />DISTRIBUTION <br />SECTION <br />MAIN/UTILITY METER <br />UGPS <br />5 <br />FEED <br />FOR <br />FUTURE <br />TRAILER <br />FEED TO FOOD TRAILER, <br />TRAILER PANEL BY OTHERS <br />11 <br />11 <br />11 <br />1SINGLE LINE DIAGRAM SCALE <br />NTS <br />1.ALL ELECTRICAL EQUIPMENT AND FEEDERS ARE NEW <br />UNLESS OTHERWISE NOTED AS "(E)" FOR EXISTING. <br />2.SWITCHBOARD SHOWN ON THE SINGLE LINE DIAGRAM <br />SHALL BE "FULLY-RATED" ADEQUATE FOR THE MAXIMUM <br />FAULT CURRENT AVAILABLE AT THE POINT OF APPLICATION, <br />INCORPORATING THE CURRENT LIMITING DEVICES AS <br />SPECIFIED. "SERIES-RATING" FOR PANELBOARDS IS <br />ACCEPTABLE. PROVIDE REQUIRED MARKING AS REQUIRED <br />PER NEC ARTICLE 110.22(B) & (C) FOR SIGNAGE AT ALL <br />PANELS AND EQUIPMENT. IF NOT "FULLY-RATED SYSTEM" <br />CONTRACTOR SHALL SUBMIT SHOP DRAWINGS INDICATING <br />SERIES RATING AND INCLUDE A COPY OF ALL LABELING, <br />INCLUDING RESPECTIVE UL LISTING, TO THE AHJ FOR <br />REFERENCE. <br />3.PROVIDE PHENOLIC NAMEPLATE LABELING & TYPE WRITTEN <br />PANEL DIRECTORY FOR ALL PANELS (EXISTING OR NEW). <br />4.INTERIOR METAL PIPING SYSTEM SHALL BE BONDED TO THE <br />GROUNDING ELECTRODE SYSTEM. <br />5.GROUND AND NEUTRAL SHALL ONLY BE BONDED AT THE <br />SERVICE EQUIPMENT AND AT THE SEPARATELY DERIVED <br />SYSTEM. <br />6.CONTRACTOR TO VERIFY THE INTEGRITY OF THE EXISTING <br />GROUNDING ELECTRODE SYSTEM AND SUBMIT FINDINGS TO <br />ELECTRICAL ENGINEER FOR REVIEW. <br />7.EQUIPMENT LINE-UP IS BASED ON SQUARE D PRODUCTS. <br />ALTERNATE MANUFACTURER IS ACCEPTABLE PROVIDED <br />THAT IT MEETS THE DESIGN INTENT AND CLEARANCE <br />REQUIREMENTS. <br />8.TRANSFORMERS SHALL NOT BE LOCATED MORE THAN 25'-0" <br />AWAY WITHOUT SECONDARY OVERCURRENT PROTECTION. <br />9.TYPICAL WIRING FOR EMERGENCY SOURCE SHALL BE <br />INDEPENDENT FROM NORMAL AND OPTIONAL SYSTEMS PER <br />NEC 700.10. <br />10.ONLY U.L LISTED EQUIPMENT SHALL BE USED. <br />11.PROVIDE ALL NECESSARY SIGNAGE, LABELING AND <br />PLAQUES AS REQUIRED BY NEC 230.70(B), 695 & 700. <br />12.ELECTRICAL CONTRACTOR TO PROVIDE MAIN LUGS & <br />ADAPTOR LUGS AS NEEDED FOR CONNECTIONS AT PANEL <br />BOARDS AND EQUIPMENT. <br />13.ELECTRICAL CONTRACTOR TO PROVIDE ALL FUSES AS <br />REQUIRED. <br />14.ALL METERING EQUIPMENTS SHALL BE SUBMITTED TO THE <br />UTILITY PROVIDER FOR APPROVAL. <br />15.INSTALL ENGRAVED BAKELITE NAMEPLATE ON SERVICE <br />DISCONNECT SWITCH IN LANDLORD'S SWITCHGEAR WITH <br />DEMISED PREMISES' SPACE NUMBER. <br />16.COMPLY WITH NEC ARTICLE 240.87 (ARC ENERGY <br />REDUCTION REQUIREMENT) <br />17.PROVIDE ARC FLASH CALCULATION AND ARC FLASH HAZARD <br />WARNING LABEL ON SWITCHBOARD IN ACCORDANCE WITH <br />NEC 110.16 <br />18.PROVIDE LABELING INDICATING POWER SOURCE ORIGIN <br />FOR ALL EQUIPMENT, SWITCHBOARDS AND PANELS <br />SUPPLIED BY FEEDER PER NEC 408.4B. <br />19.PROVIDE A COORDINATION STUDY OF ALL PROTECTIVE <br />DEVICES, INCLUDING UTILITY PROTECTIVE DEVICE THROUGH <br />ALL FEEDER DEVICES ON THE SECONDARY OF THE <br />TRANSFORMER. STUDY TO BE PRESENTED ON LOG-LOG <br />PAPER. UPON REVIEW OF THE STUDY, CONTRACTOR SHALL <br />SET DEVICES AT AGREED UPON SETTINGS AND PROVIDE A <br />DATA SHEET TO OWNER'S REPRESENTATIVE INDICATING <br />FINAL SETTINGS FOR ALL ADJUSTABLE DEVICES. THE <br />COORDINATION STUDY SHALL BE SUBMITTED WITH SHORT <br />CIRCUIT STUDY AND BEFORE FEEDERS ARE BEING <br />INSTALLED ON SITE. THIS STUDY SHALL BE CARRIED OUT BY <br />THE SWITCHBOARD MANUFACTURER. THE COST OF THE <br />STUDY SHALL BE INCLUDED AS PART OF THE CONTRACT. <br />GENERAL NOTES: <br />A.NEW PAD MOUNTED UTILITY TRANSFORMER. CONTRACTOR TO <br />COORDINATE WITH UTILITY CO. REPRESENTATIVE FOR ALL WORK <br />REQUIRED FOR THE NEW SERVICE INSTALLATION. <br />B.GROUNDING ELECTRODE SYSTEM: CONNECT TO (E) GROUNDING <br />ELECTRODE SYSTEM USING #3/0. PROVIDE (3) 3/4" X 120" COPPER CLAD <br />GROUND ROD - MINIMUM 72" APART. USE #4 CU WIRE FOR SOLE <br />CONNECTION TO GROUND ROD. UNDERGROUND METAL WATER PIPE <br />(WITHIN 5' OF ENTRANCE TO BUILDING), ALL METAL PIPING SYSTEM, <br />CONTIGUOUS STRUCTURAL METAL (IF PRESENT) SHALL BE BONDED TO <br />THE GROUNDED ELECTRODE SYSTEM IN MAIN ELECTRICAL ROOM <br />USING #3/0. PROVIDE ADDITIONAL GROUNDING ELECTRODE WHERE <br />RESISTANCE TO GROUND EXCEEDS 25 OHMS. <br />C.PROVIDE AN ENERGY REDUCING MAINTENANCE SWITCH WITH LOCAL <br />STATUS INDICATOR THAT, WHEN TURNED ON, REDUCES THE <br />INSTANTANEOUS PICKUP SETTING TO NO MORE THAN TWO TIMES THE <br />SENSOR AMPERAGE TO BREAKER PER NEC 240.87 ARC-ENERGY <br />REDUCTION MAINTENANCE SYSTEM. <br />SINGLE LINE KEY NOTES:X <br />1.UTILITY TRANSFORMER AND PAD INSTALLED BY OTHERS <br />2.PROVIDE (7) SETS OF 5"C.O. FROM UTILITY TRANSFORMER TO <br />SWITCHBOARD SHALL BE INSTALLED BY THE ELECTRICAL CONTRACTOR. <br />POWER CABLES AND FINAL CONNECTIONS BY PG&E. TRENCHING AND <br />BACKFILLING BY G.C. COORDINATE REQUIREMENTS WITH UTILITY PLANS. <br />3.PROVIDE 8' H x 3/4" THICK x 4' W PER PLAN FIRE-RATED PLYWOOD <br />TELEPHONE BACKBOARD. SEE SPECIFICATIONS FOR MORE INFORMATION. <br />MOUNT FROM THE CEILING DOWN. PAINT COLOR AS SELECTED BY <br />ARCHITECT. ARCHITECT SHALL SPECIFY PAINT. LEAVE (1) FIRE RATING <br />STAMP EXPOSED ON EACH PIECE OF PLYWOOD. <br />4.PROVIDE WATTSTOPPER LP8 LIGHTING CONTROL PANEL WITH LMCP24 <br />ENCLOSURE. PROVIDE CONTACTORS AS REQUIRED. REFER TO <br />CONTACTOR SCHEDULE FOR MORE INFORMATION. <br />5.PROVIDE WEATHERPROOF DUPLEX RECEPTACLE AND TAYMAC MM510C <br />SINGLE-GANG VERTICAL WEATHERPROOF WHILE IN USE OUTLET COVER <br />FOR IRRIGATION CONTROLLER. COORDINATE EXACT LOCATION WITH <br />ARCHITECT PRIOR TO ROUGH-IN. <br />6.PROVIDE ANSI-J-STD 607A COMPLIANT U.L.-LISTED TELECOMMUNICATIONS <br />MAIN GROUND BUSBAR (TMGB) & TELECOMMUNICATIONS BONDING <br />BACKBONE (TBB) PER ANSI-J-STD-607-A. GROUND AND BOND ALL TRAY, <br />CABINETS, PDUS, UPS, HVAC SYSTEMS ETC. SEE TELECOM PATHWAY AND <br />GROUNDING RISER PLAN (IF PROVIDED) FOR MORE INFORMATION. <br />7.PROVIDE (2) 4" CONDUIT STUB WITH PULL STRING FOR TELCOM <br />CONNECTION. COORDINATE WORK WITH DRY UTILITY AND JOINT TRENCH <br />CONSULTANT. <br />8.LOCATION FOR CHARGEPOINT CT4000 SERIES, SINGLE HEAD <br />9.LOCATION FOR CHARGEPOINT CT4000 SERIES, DUAL HEAD <br />10.LOCATION OF 2500A 120/208V ELECTRICAL SERVICE <br />11.PROVISIONS FOR ELECTRIC HEATERS, FIRE PIT, WATER FEATURE AND <br />PERFORMANCE STAGE. CONNECTIONS SHALL BE COORDINATED IN <br />SEPARATE PERMIT PACKAGE. <br />SITE PLAN KEY NOTES:X <br />MINIMUM REQUIRED PV PER TITLE 24 140.10-A <br />KW = (CFA X A) / 1000 <br />CFA - CONDITIONED FLOOR AREA <br />A - PV CAPACITY FACTOR PER TABLE 140.10-A (CLIMATE ZONE 12, RESTAURANT) <br />KW = (8661 SQFT X 0.44) / 1000 = 3.81 KW <br /><4 KW EXEMPT FROM PV SYSTEM REQUIREMENT. <br />MINIMUM REQUIRED BATTERY PER TITLE 24 140.10-B <br />KWH = KW X B / SQRT ( D ) <br />B - BATTERY ENERGY CAPACITY FACTOR PER TABLE 140.10-B <br />D - RATED SINGLE CHARGE DISCHARGE CYCLE AC-AC EFFICENCY OF THE BATTERY <br />STORAGE SYSTEM <br />KWH = 3.81KW X 0.03 / SQRT(.95) = 3.64KWH <br /><10KWH EXEMPT FROM BATTERY REQUIREMENT. <br />3SITE PLAN SCALE <br />3/16" = 1' - 0" <br />ISSUANCE & REVISIONS <br />All drawings and written material appearing herein constitute the <br />original and unpublished work of the architect and the same may <br />not be duplicated, used, or disclosed without the written consent of <br />the architect © Field Paoli <br />SHEET NUMBER: <br />JOB NO. <br />CHECKED BY <br />DRAWN BY <br />NOT FOR CONSTRUCTION <br />SCHEMATIC DESIGN <br />231562 <br />NO.DESCRIPTION DATE <br />DESIGN REVIEW SUBMITTAL 07.17.2024 <br />SCHEMATIC DESIGN ISSUANCE 07.18.2024 <br />DESIGN REVIEW RESUBMITTAL 09.13.2024 <br />PRICING SET PROGRESS 09.20.2024 <br />PERMIT PROGRESS SET 11.22.2024 <br />DESIGN REVIEW RESUBMITTAL 01.13.2025 <br />E5.0 <br />SINGLE LINE <br />DIAGRAM AND <br />SITE PLAN <br />NEW <br />UTILITY <br />TRANSFORMER <br />(7) SETS OF 5"C.O. WITH PULL STRING <br />2500A <br />3P <br />MCB <br />GFI <br />MAIN SWITCHBOARD MSB: IN A NEMA-3R 2500A GFI MCB, 120/208V, 3PH, 4W, 65KAIC <br />AIC RATING CONTINGENT ON PG&E AIC LETTER <br />A <br />B <br />CM <br />PROVISION FOR <br />FUTURE PV SYSTEM <br />TO SOLAR <br />INVERTER <br />400A <br />3P <br />PANEL <br />A <br />400A <br />3P <br />PANEL <br />B <br />400A <br />3P <br />PANEL <br />C <br />600A <br />3P <br />PANEL <br />D <br />400A <br />3P <br />400A <br />3P <br />FUTURE <br />FOOD <br />TRAILER <br />FOOD <br />TRAILER <br />BY <br />OTHERS <br />2500A <br />3P <br />KIRK <br />KEY <br />INTERLOCK <br />ISSUANCE & REVISIONS <br />CONSTRUCTION DOCUMENTS <br />NO. DESCRIPTION DATE <br />DESIGN REVIEW SUBMITTAL 07.17.2024 <br />1 DESIGN REVIEW RESUBMITTAL 09.13.2024 <br />2 DESIGN REVIEW RESUBMITTAL 02.07.2025
The URL can be used to link to this page
Your browser does not support the video tag.