My WebLink
|
Help
|
About
|
Sign Out
Planning Commission Agenda Packet 102225 (1)
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
AGENDA PACKETS
>
2020 - PRESENT
>
2025
>
10-22
>
Planning Commission Agenda Packet 102225 (1)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/30/2025 4:35:02 PM
Creation date
12/30/2025 4:30:37 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
296
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> May 2025 2 City of Pleasanton <br />5859 Owens Drive <br />Fire Flow Analysis <br /> <br />PURPOSE <br />The purpose of this technical memorandum is to provide the recipient with an <br />understanding of the capabilities of the City of Pleasanton’s water distribution system <br />under fire flow conditions. The hydraulic model evaluates the maximum flow capacity of <br />the distribution system at the closest hydrant to 5859 Owens Drive. The analysis below <br />includes a modeled simulation of four different scenarios highlighting the flow and <br />residual pressure in each scenario respectively. <br />Scenario 1: The first scenario is under static conditions where the system is in its <br />existing state with no fire flow stressors. <br />Scenario 2: The second scenario is under the design fire flow which is prescribed by <br />the System Performance and Design Criteria based on the City’s Water Distribution <br />Capacity Master Plan. The design fire flow is applied to determine if the distribution <br />system is capable of supplying both the minimum required flow and its resultant residual <br />pressure with no constraints applied. <br />Scenario 3: The third scenario is under the 20.0 psi system wide minimum pressure <br />during fires which is prescribed by the System Performance and Design Criteria based <br />on the City’s Water Distribution Capacity Master Plan. This scenario is a test to <br />determine the maximum flow the distribution system is capable of supplying at the <br />hydrant location while maintaining the 20.0 psi minimum pressure constraint. <br />Scenario 4: The fourth scenario is under both the 20.0 psi minimum pressure constraint <br />as well as the maximum velocity constraint of 10.0 ft/s which are prescribed by the <br />System Performance and Design Criteria based on the City’s Water Distribution <br />Capacity Master Plan. This scenario is a test to determine the maximum flow the <br />distribution system is capable of supplying at the hydrant location while maintaining both <br />the 20.0 psi minimum pressure constraint and the 10.0 ft/s maximum velocity constraint. <br />By adding constraints to each of the scenarios, we are able to identify any limiting <br />factors hindering the maximum flow the distribution system is capable of supplying at <br />the specified hydrant location. <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.