Testing, Sampling, and Analysis Plan <br />January 15, 2025 <br />7 <br />Zone 7 Water Agency and <br />City of Pleasanton <br />4. EQUIPMENT, CALIBRATION, AND DECONTAMINATION <br />4.1. Equipment <br />Field personnel shall be adequately equipped to perform field activities described herein. The following <br />list is not a comprehensive list of all instrumentation, equipment, gear, and consumables that may be <br />needed to complete the field activities. The list merely states key items that are specific to this project <br />1.Electrical sounder with 0.01-foot graduation to support direct readings with a resolution of 0.01 foot. <br />2.Multi-parameter water quality meter or individual sensors for measurement of specific conductance <br />(SP), temperature, (T), pH, oxygen reduction potential (ORP), and dissolved oxygen (DO). <br />3.Turbidity meter <br />4.Consumables such as powder-free nitrile gloves and single-use in-ůŝŶĞĨŝůƚĞƌƐ;Ϭ͘ϰϱʅŵͿ͘ <br />5.Decontamination supplies including Alconox® (or other phosphate-free detergent) and deionized water. <br />All instrumentation is to have manufacturers’ specifications for accuracy and precision reflective of <br />standards commonly used in environmental groundwater monitoring applications comparable to the <br />Zone 7 sites. Instrumentation is to be kept clean and to be stored and handled appropriately. <br />4.2. Calibration <br />Shop and field calibration of instrumentation shall be conducted following the manufacturer’s instructions <br />and guidelines using appropriate standard solutions (primary and secondary, as appropriate) and <br />procedures and at manufacturer-recommended intervals. Documentation of calibration activities shall <br />recorded on specified forms (Section 6). The electrical sounder and thermometer are factory-calibrated <br />and do not require calibration by the user. The ORP sensor shall be cleaned and conditioned according to <br />the manufacturer’s instructions. <br />4.3. Decontamination <br />Prior to the first use at the Zone 7 sites, the portion of the electrical sounder that will be entering the wells <br />shall be washed with an Alconox® (or a comparable phosphate-free detergent) solution and thoroughly <br />rinsed with deionized water. The portion of the electrical sounder that enters the well is not to contact <br />the ground or otherwise be subjected to potential contamination. Between wells, the portion of the <br />electrical sounder that entered the well is to be thoroughly rinsed with deionized water. <br />The portions of water quality meters and individual sensors that come into contact with purged water <br />shall be thoroughly rinsed with deionized water between wells. <br />5. PROCEDURES AND SAMPLE COLLECTION <br />Upon arrival at each test well site, the well identification shall be checked against project information <br />(e.g., location map, description, or photographs). The well structure shall inspected for evidence of <br />damage, tampering, and vandalism.