My WebLink
|
Help
|
About
|
Sign Out
PC-2026-15
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
RESOLUTIONS
>
2020 - PRESENT
>
2026
>
PC-2026-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2026 12:52:06 PM
Creation date
8/5/2026 12:48:39 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
RESOLUTIONS
DOCUMENT DATE
6/24/2026
DESTRUCT DATE
PERMANENT
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
444
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
330 Land Company, LLC Arroyo Lago <br />9785.004.001 Design-Level Geotechnical Report <br /> <br /> <br /> Page | 19 April 16, 2024 <br />Latest Revision October 31, 2025 <br />Jetting of backfill is not an acceptable means of compaction. We may allow thicker loose lift <br />thicknesses, based on acceptable density test results, where increased effort is applied to rocky <br />fill or for the first lift of fill over pipe bedding. <br /> <br />5.8 GRADED SLOPES <br /> <br />In general, cut slopes less than 4 feet high and graded slopes less than 10 feet high should be <br />no steeper than 2:1 (horizontal:vertical). All fill slopes should be adequately keyed into firm <br />materials unaffected by shrinkage cracks. Fill slopes should be over-built and then trimmed back <br />to finished grades. If a cut or cut-fill transition occurs within a graded slope, we recommend the <br />slope be overexcavated and reconstructed as an engineered fill slope. <br /> <br />The contractor is responsible for constructing temporary construction slopes in accordance with <br />Cal/OSHA requirements. <br /> <br />5.9 SURFACE DRAINAGE <br /> <br />The project civil engineer is responsible for designing surface drainage improvements. With <br />regard to geotechnical engineering issues, we recommend that finish grades be sloped away from <br />buildings and pavements to the maximum extent practical to reduce the potentially damaging <br />effects of soil shrink and swell. The latest California Building Code Section 1804.4 specifies <br />minimum slopes of 5 percent away from foundations within 10 feet for unpaved conditions. Where <br />lot lines or surface improvements restrict meeting this slope requirement, we recommend that <br />specific drainage requirements be developed. <br /> <br />As a minimum, we recommend the following. <br /> <br />1. Roof downspouts should discharge into closed conduits and direct away from foundations to <br />appropriate drainage devices. <br />2. Water should not be allowed to pond near foundations, pavements, or exterior flatwork. <br /> <br />5.10 STORMWATER BIOTREATMENT AND INFILTRATION <br /> <br />We encountered moderately to highly expansive clay near the ground surface. Thus, the existing <br />site soil is not expected to have adequate permeability for stormwater infiltration, unless subdrains <br />are installed. We recommend assuming little stormwater infiltration will occur through the existing <br />site soil. <br /> <br />If bioretention areas are implemented, we recommend that, when practical, they be planned a <br />minimum of 5 feet away from structural site improvements, such as buildings, streets, retaining <br />walls, and sidewalks/driveways. When this is not practical, bioretention areas located within 5 feet <br />of structural site improvements can either: <br /> <br />1. Be constructed with structural side walls capable of withstanding the loads from the adjacent <br />improvements, or <br />2. Incorporate filter material compacted to between 85 and 90 percent relative compaction <br />(ASTM D1557, latest edition) and a waterproofing system designed to reduce the potential for <br />moisture transmission into the subgrade soil beneath the adjacent improvemen t. <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.