My WebLink
|
Help
|
About
|
Sign Out
CITY COUNCIL SPECIAL MEETING AGENDA PACKET 8-11-26
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2026
>
081126 SPECIAL
>
CITY COUNCIL SPECIAL MEETING AGENDA PACKET 8-11-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/7/2026 9:09:20 AM
Creation date
8/7/2026 8:56:02 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
8/11/2026
DESTRUCT DATE
15Y
DOCUMENT NAME
SPECIAL MEETING AGENDA PACKET
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
373
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LIVERMORE-PLEASANTON Attachment 2 <br />LPFD <br />FIRE DEPARTMENT <br />Office of the Fire Marshal <br />Exterior Emergency Escape and Rescue Opening Access <br />When exterior emergency escape and rescue openings are required by code, they shall be accessible by <br />ladder as follows: <br />1. <br />2. <br />Provide straight access (compliant stairs may be used); 6 feet wide to court(s) harboring rescue <br />windows. Illustrate that a 35 foot extension ladder folded to it's carrying size of 14'-0" long by 2'-3" <br />wide by 1'-0" thick, carried by a 3 person team can be maneuvered into all locations with rescue <br />windows. <br />All rescue windows must be accessible. A Stable, Slip Resistant, Level Fire Ladder location (Pad) <br />capable of supporting the weight of the ladder, the firefighter in gear, equipment, and the person to be <br />rescued (no less than 600 pounds total). Pads may be of grass crete, gravel or other permeable materials <br />capable of supporting the ladder without slipping. This Fire Ladder Pad shall be no less than 6'-0" wide <br />by 7'-0" deep and shall allow the unobstructed raising of the ladder free of overhead obstacles. The <br />extended ladder angle must be at least 70° from horizontal or 4:1 slope unless otherwise approved. <br />Provide elevation and plan views with ladder details. <br />4 <br />3rd Floor <br />Floc <br />3rd Floar 3rd Floo <br />Podiuti Level(2nd Floc)Podium Level <br />{2nd Floог)Podium Level(2nd Floor) <br />Ire lodder -fre lodcec -fire lodder <br />-retaining wal atraised <br />Garage <br />(1st Roor)2 Gorog <br />(1s: Floor)2% <br />4' <br />Gorege(1at Floo-)curb <br />eg <br />r <br />e <br />s <br />s <br />herd surfoced padsurioced dd(concrete or unit pavars) <br />fire lodder(to 3rd floerk <br />-hard suraced pad <br />-fire ladder(to re floor) <br />(cencrete, unit paverg <br />or DO) <br />10'-2' <br />public r.o.w <br />planting ares <br />fire Icdder (ta 3rd floor) <br />herd eufacec pad <br />city sterdrda <br />4 <br />publa righ: o way <br />Fire Ladder Pad Diagrams <br />3. The installed Fire Ladder Pads shall be permanently marked "Fire Ladder Pad". <br />DOCUMENT REVISIONS <br />This document is subject to revisions. For general information and to verify that you have the most current document, please call <br />(925) 454-2361, and request the current version. <br />LIVERMORE-PLEASANTON <br />3560 Nevada Street Pleasanton, CA 94566 Ph: (925) 454-2361 Fax: (925) 454-2367 www.lpfire.org <br />2/2/2016 <br />FIKE DEPART <br />Page 325 of 373
The URL can be used to link to this page
Your browser does not support the video tag.