Laserfiche WebLink
PC Resolution No. PC-2026-26 September 23, 2026 <br />Standards able to suppress a major fire. <br /> <br />114. HAZARDOUS MATERIALS: Should any operation or business activity involve <br />the use, storage or handling of hazardous materials, the firm shall be responsible <br />for contacting the Livermore-Pleasanton Fire Department prior to commencing <br />operations. Please contact the Hazardous Materials Coordinator at 925-454- <br />2361. <br /> <br />115. FIRE HYDRANTS: Fire hydrants shall be installed at spacing not greater than <br />300 feet in industrial and commercial developments. Fire hydrants shall be <br />installed at spacing not greater than 400 feet in residential developments. <br /> <br />116. FIRE LANE MARKING: On-site access ways, turn arounds, and internal drives <br />shall be designated as fire lanes and identified as such by red curb striping and <br />posted with signs at locations approve by the Fire Department. Signs shall be <br />according to State standards and read “No Parking – Fire Lane” and must be <br />shown on the plans. The red curb striping, sign location(s), and sign language <br />shall be included in the building permit submittal for review and approval by the <br />Livermore-Pleasanton Fire Department prior to building permit issuance. <br />a. The following schedule for NO PARKING signs shall apply: <br /> <br />Width Requirements <br />36 feet or greater No requirements <br /> <br />Between 28 and 36 feet Post one side <br />Between 20 and 28 feet Post both sides <br />Less than 20 feet Not permitted <br />Cul-de-Sac Not permitted <br />117. EMERGENCY VEHICLE ACCESS ROADS: Access roads shall have 13 feet, 6 <br />inches unobstructed vertical clearance, 20 feet of unobstructed width (26 feet <br />where occupied building floors exceed 30 feet height), and inside turning radius <br />of 31 feet and outside turning radius of 51 feet. Unobstructed shall mean a clear <br />travel way, excluding parking width, and designed for an emergency vehicle <br />weight of 70,000 pounds under all weather conditions. Unobstructed width shall <br />not include the width of rolled curbs, sidewalks, or non-drivable surfaces. All <br />exterior portions of buildings must be within 200 feet of an access road. Yard and <br />parking area may be able to be located farther than 200 feet from access roads, <br />depending on the specific use. <br /> <br />118. PREMISES IDENTIFICATION: Address numbers shall be installed on the front or <br />primary entrance for all buildings. Minimum building address character size shall <br />be 12-inch high by 1-inch stroke. In all cases address numerals shall be of <br />Docusign Envelope ID: A549EA74-ED4F-8CB2-8262-A310230CC465