My WebLink
|
Help
|
About
|
Sign Out
2003 APRIL
City of Pleasanton
>
CITY CLERK
>
MUNICIPAL CODE SUPPLEMENTS
>
2003 APRIL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2009 2:04:58 PM
Creation date
7/13/2007 1:34:48 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
CODE SUPPLEMENTS
DOCUMENT DATE
2/20/2002
DOCUMENT NO
2003 APRIL
DOCUMENT NAME
SUPPLEMENT NO 12
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.20.027 <br />Interruption. The ground-fault pro- <br />tection device or system shall be <br />capable of detecting a ground fault, <br />interrupting the flow of fault current, <br />and providing an indication of the <br />fault. <br />(B) Disconnection of Conductors. <br />The ungrounded conductors of the <br />faulted source circuit shall be auto- <br />matically disconnected. If the <br />grounded conductors of the faulted <br />source circuit are disconnected to <br />comply with the requirements of <br />690.5(A), all conductors of the fault- <br />ed source circuit shall be opened <br />automatically and simultaneously. <br />Opening the grounded conductor of <br />the array or opening the faulted sec- <br />tions of the array shall be permitted <br />to interrupt the ground-fault current <br />path. <br />(C) Labels and Markings. Labels and <br />markings shall be applied near the <br />ground-fault indicator at a visible <br />location, stating that, if a ground <br />fault is indicated, the normally <br />grounded conductors may be ener- <br />gized and ungrounded. <br />690.6 Alternating-Current Modules. <br />(A) Photovoltaic Source Circuits. <br />The requirements of Article 690 per- <br />taining to photovoltaic source cir- <br />cuits shall not apply to ac modules. <br />The photovoltaic source circuit, <br />conductors, and inverters shall be <br />considered as internal wiring of an ac <br />module. <br />(B) Inverter Output Circuit. The out- <br />put of an ac module shall be consid- <br />ered an inverter output circuit. <br />(C) Disconnecting Means. A single <br />disconnecting means, in accordance <br />with 690.15 and 690.17, shall be <br />permitted for the combined ac output <br />of one or more ac modules. Addi- <br />tionally, each ac module in a multi- <br />ple ac-module system shall be pro- <br />vided with a connector, bolted, or <br />terminal type disconnecting means. <br />(D) Ground-Fault Detection. Alter- <br />nating-current-module systems shall <br />be permitted to use a single detection <br />device to detect only ac ground <br />faults and to disable the array by <br />removing ac power to the ac mod- <br />ule(s). <br />(E) Over current Protection. The <br />output circuits of ac modules shall be <br />permitted to have over current pro- <br />tection and conductor sizing in ac- <br />cordance with 240.5(B)(2). <br />II. Circuit Requirements <br />690.7 Maximum Voltage. <br />(A) Maximum Photovoltaic System <br />Voltage. In a do photovoltaic source <br />circuit or output circuit, the maxi- <br />mum photovoltaic system voltage for <br />that circuit shall be computed as the <br />sum of the rated open-circuit voltage <br />of the series connected photovoltaic <br />modules corrected for the lowest <br />expected ambient temperature. For <br />710-17 (Pleasanton April 2003) <br />