My WebLink
|
Help
|
About
|
Sign Out
2003 APRIL
City of Pleasanton
>
CITY CLERK
>
MUNICIPAL CODE SUPPLEMENTS
>
2003 APRIL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2009 2:04:58 PM
Creation date
7/13/2007 1:34:48 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
CODE SUPPLEMENTS
DOCUMENT DATE
2/20/2002
DOCUMENT NO
2003 APRIL
DOCUMENT NAME
SUPPLEMENT NO 12
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.20.027 <br />assembly, together with its over <br />current device(s), that is listed for <br />continuous operation at 100 per- <br />cent of its rating shall be permit- <br />ted to be utilized at 100 percent of <br />its rating. <br />(2) Internal Current Limitation. Over <br />current protection for photovoltaic <br />output circuits with devices that <br />internally limit the current from the <br />photovoltaic output circuit shall be <br />permitted to be rated at less than the <br />value computed in 690.8(B)(1). This <br />reduced rating shall be at least 125 <br />percent of the limited current value. <br />Photovoltaic output circuit conduc- <br />tors shall be sized in accordance with <br />690.8(B)(1). <br />Exception: An over current device in <br />an assembly listed for continuous <br />operation at 100 percent of its rating <br />shall be permitted to be utilized at <br />100 percent of its rating. <br />(C) Systems with Multiple Direct- <br />Current Voltages. For a photovoltaic <br />power source that has multiple out- <br />put circuit voltages and employs a <br />common-return conductor, the <br />ampacity of the common-return con- <br />ductor shall not be less than the sum <br />of the ampere ratings of the over <br />current devices of the individual <br />output circuits. <br />(D) Sizing of Module Interconnec- <br />tion Conductors. Where a single over <br />current device is used to protect a set <br />of two or more parallel-connected <br />module circuits, the ampacity of each <br />of the module interconnection con- <br />ductors shall not be less than the sum <br />of the rating of the single fuse plus <br />125 percent of the short-circuit cur- <br />rent from the other parallel-connect- <br />ed modules. <br />690.9 Over current Protection. <br />(A) Circuits and Equipment. Photo- <br />voltaic source circuit, photovoltaic <br />output circuit, inverter output circuit, <br />and storage battery circuit conductors <br />and equipment shall be protected in <br />accordance with the requirements of <br />Article 240. Circuits connected to <br />more than one electrical source shall <br />have over current devices located so <br />as to provide over current protection <br />from all sources. <br />Exception: An over current device <br />shall not be required for circuit <br />conductors sized in accordance <br />with 690.8(B) and located where <br />one of the following apply: <br />(a) There are no external sourc- <br />es such as parallel-connected <br />source circuits, batteries, or <br />back feed from inverters. <br />(b) The short-circuit currents <br />from all sources do not exceed <br />the ampacity of the conductors. <br />FPN: Possible back feed of cur- <br />rent from any source of supply, <br />including a supply through an <br />inverter into the photovoltaic <br />output circuit and photovoltaic <br />source circuits, is a consideration <br />in determining whether adequate <br />over current protection from all <br />sources is provided for conductors <br />and modules. <br />(Pleasanton April 2003) '] 10_2, <br />
The URL can be used to link to this page
Your browser does not support the video tag.