My WebLink
|
Help
|
About
|
Sign Out
2003 APRIL
City of Pleasanton
>
CITY CLERK
>
MUNICIPAL CODE SUPPLEMENTS
>
2003 APRIL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2009 2:04:58 PM
Creation date
7/13/2007 1:34:48 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
CODE SUPPLEMENTS
DOCUMENT DATE
2/20/2002
DOCUMENT NO
2003 APRIL
DOCUMENT NAME
SUPPLEMENT NO 12
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.20.027 <br />(B) Power Transformers. Over cur- <br />rent protection for a transformer with <br />a source(s) on each side shall be pro- <br />vided in accordance with 450.3 by <br />considering first one side of the <br />transformer, then the other side of <br />the transformer, as the primary. <br />Exception: A power transformer <br />with a current rating on the side <br />connected toward the photovoltaic <br />power source not less than the <br />short-circuit output current rating <br />of the inverter shall be permitted <br />without over current protection <br />from that source. <br />(C) Photovoltaic Source Circuits. <br />Branch-circuit or supplementary-type <br />over current devices shall be permit- <br />ted to provide over current protection <br />in photovoltaic source circuits. The <br />over current devices shall be accessi- <br />ble but shall not be required to be <br />readily accessible. <br />Standard values of supplementary <br />over current devices allowed by this <br />section shall be in one-ampere size <br />increments starting at one ampere up <br />to and including 15 amperes. Higher <br />standard values above 15 amperes for <br />supplementary over current devices <br />shall be based on the standard sizes <br />provided in 240.6(A). <br />(D) Direct-Current Rating. Over cur- <br />rent devices, either fuses or circuit <br />breakers, used in any do portion of a <br />photovoltaic power system shall be <br />listed for use in do circuits and shall <br />have the appropriate voltage, current, <br />and interrupt ratings. <br />(E) Series Over current Protection. In <br />series-connected strings of two or <br />more modules, a single over current <br />protection device shall be permitted. <br />690.10 Stand-Alone Systems. <br />The premises wiring system shall be <br />adequate to meet the requirements of <br />this Code for a similar installation <br />connected to a service. The wiring on <br />the supply side of the building or <br />structure disconnecting means shall <br />comply with this Code except as <br />modified by 690.10(A), (B), and (C). <br />(A) Inverter Output. The ac inverter <br />output from a stand-alone system <br />shall be permitted to supply ac power <br />to the building or structure discon- <br />necting means at current levels below <br />the rating of that disconnecting <br />means. <br />(B) Sizing and Protection. The cir- <br />cuit conductors between the inverter <br />output and the building or structure <br />disconnecting means shall be sized <br />based on the output rating of the <br />inverter. These conductors shall be <br />protected from over currents in ac- <br />cordance with Article 240. The over <br />current protection shall be located at <br />the output of the inverter. <br />(C) Single 120-Volt Supply. The <br />inverter output of a stand-alone solar <br />photovoltaic system shall be permit- <br />ted to supply 120 volts to single- <br />phase, 3-wire, 120/240-volt service <br />equipment or distribution panels <br />where there are no 240-volt outlets <br />and where there are no multi-wire <br />710-21 (Pleasanton April 2003) <br />