My WebLink
|
Help
|
About
|
Sign Out
2003 APRIL
City of Pleasanton
>
CITY CLERK
>
MUNICIPAL CODE SUPPLEMENTS
>
2003 APRIL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2009 2:04:58 PM
Creation date
7/13/2007 1:34:48 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
CODE SUPPLEMENTS
DOCUMENT DATE
2/20/2002
DOCUMENT NO
2003 APRIL
DOCUMENT NAME
SUPPLEMENT NO 12
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.20.027 <br />(4) Maximum Number of Discon- persons. Such a fuse in a photovolta- <br />nects. The photovoltaic system is source circuit shall be capable of <br />disconnecting means shall consist being disconnected independently of <br />of not more than six switches or fuses in other photovoltaic source <br />six circuit breakers mounted in a circuits. <br />single enclosure, in a group of <br />separate enclosures, or in or on a 690.17 Switch or Circuit Breaker. <br />switchboard. <br /> The disconnecting means for un- <br />(5) Grouping. The photovoltaic grounded conductors shall consist of <br />system disconnecting means shall a manually operable switch(es) or <br />be grouped with other disconnect- circuit breaker(s) complying with all <br />ing means for the system to com- of the following requirements: <br />ply with 690.14(C)(4). A pho- <br />tovoltaic disconnecting means (1) Located where readily accessi- <br />shall not be required at the pho- ble <br />tovoltaic module or array location. (2) Externally operable without <br /> exposing the operator to contact <br />690.15 Disconnection of Photovoltaic with live parts <br />Equipment. (3) Plainly indicating whether in <br /> the open or closed position <br />Means shall be provided to discon- (4) Having an interrupting rating <br />nect equipment, such as inverters, sufficient for the nominal circuit <br />batteries, charge controllers, and the voltage and the current that is <br />like, from all ungrounded conductors available at the line terminals of <br />of all sources. If the equipment is the equipment <br />energized from more than one <br />source, the disconnecting means shall Where all terminals of the discon- <br />be grouped and identified. necting means may be energized in <br />A single disconnecting means in the open position, a warning sign <br />accordance with 690.17 shall be shall be mounted on or adjacent to <br />permitted for the combined ac output the disconnecting means. The sign <br />of one or more inverters or ac mod- shall be clearly legible and have the <br />ules in an interactive system. following words or equivalent: <br />690.16 Fuses. WARNING. <br />ELECTRIC SHOCK HAZARD. <br />Disconnecting means shall be provid- DO NOT TOUCH TERMINALS. <br />ed to disconnect a fuse from all TERMINALS ON BOTH THE LINE <br />sources of supply if the fuse is ever- AND LOAD SIDES MAY BE <br />gized from both directions and is ENERGIZED IN THE OPEN <br />accessible to other than qualified POSITION. <br />710-23 (Pleasanton April 2003) <br />
The URL can be used to link to this page
Your browser does not support the video tag.