My WebLink
|
Help
|
About
|
Sign Out
2003 APRIL
City of Pleasanton
>
CITY CLERK
>
MUNICIPAL CODE SUPPLEMENTS
>
2003 APRIL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2009 2:04:58 PM
Creation date
7/13/2007 1:34:48 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
CODE SUPPLEMENTS
DOCUMENT DATE
2/20/2002
DOCUMENT NO
2003 APRIL
DOCUMENT NAME
SUPPLEMENT NO 12
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.20.027 <br />Exception No. 1: A disconnecting <br />means located on the do side shall <br />be permitted to have an interrupt- <br />ing rating less than the current- <br />carrying rating where the system <br />is designed so that the do switch <br />cannot be opened under load. <br />Exception No. 2: A connector <br />shall be permitted to be used as an <br />ac or a do disconnecting means <br />provided that it complies with the <br />requirements of 690.33 and is <br />listed and identified for the use. <br />690.18 Installation and Service of an <br />Array. <br />Open circuiting, short-circuiting, or <br />opaque covering shall be used to <br />disable an array or portions of an <br />array for installation and service. <br />FPN: Photovoltaic modules are <br />energized while exposed to light. <br />Installation, replacement, or ser- <br />vicing of array components while <br />a module(s) is irradiated may <br />expose persons to electric shock. <br />IV. Wiring Methods <br />690.31 Methods Permitted. <br />(A) Wiring Systems. All raceway and <br />cable wiring methods included in this <br />Code and other wiring systems and <br />fittings specifically intended and <br />identified for use on photovoltaic <br />arrays shall be permitted. Where <br />wiring devices with integral enclo- <br />sures are used, sufficient length of <br />cable shall be provided to facilitate <br />replacement. <br />(B) Single Conductor Cable. Types <br />SE, UF, USE, and USE-2 single-con- <br />ductor cable shall be permitted in <br />photovoltaic source circuits where <br />installed in the same manner as a <br />Type OF multi-conductor cable in <br />accordance with Article 339. Where <br />exposed to sunlight, Type OF cable <br />identified as sunlight-resistant shall <br />be used. <br />(C) Flexible Cords and Cables. Flexi- <br />ble cords and cables, where used to <br />connect the moving parts of tracking <br />PV modules, shall comply with Arti- <br />cle 400 and shall be of a type identi- <br />fied as a hard service cord or porta- <br />ble power cable; they shall be suit- <br />able for extra-hard usage, listed for <br />outdoor use, water resistant, and <br />sunlight resistant. Allowable <br />ampacities shall be in accordance <br />with 400.5. For ambient temperatures <br />exceeding 30°C (86°F), the <br />ampacities shall be derated by the <br />appropriate factors given in Table <br />690.31(C). <br />(D) Small-Conductor Cables. Single- <br />conductor cables listed for outdoor <br />use that are sunlight resistant and <br />moisture resistant in sizes 16 AWG <br />and 18 AWG shall be permitted for <br />module interconnections where such <br />cables meet the ampacity require- <br />ments of 690.8. Section 310.15 shall <br />be used to determine the cable <br />ampacity and temperature derating <br />factors. <br />690.32 Comyonent Interconnections. <br />Fittings and connectors that are in- <br />tended to be concealed at the time of <br />(Pleasanton April 2003) 710-24 <br />