20.20.027 <br />device rating for module protection, 690.54 Interactive System Point of <br />and with the following ratings: Interconnection. <br />(1) Open-circuit voltage All interactive system(s) points of <br />(2) Operating voltage interconnection with other sources <br />(3) Maximum permissible system shall be marked at an accessible <br />voltage location at the disconnecting means <br />(4) Operating current as a power source with the maximum <br />(5) Short-circuit current ac output operating current and the <br />(6) Maximum power operating ac voltage. <br />690.52 Alternatin>;-Current Photovol- 690.55 Photovoltaic Power Systems <br />taic Modules. Employin~ EnerQV Storage. <br />Alternating-current modules shall be Photovoltaic power systems employ- <br />marked with identification of termi- ing energy storage shall also be <br />pals or leads and with identification marked with the maximum operating <br />of the following ratings: voltage, including any equalization <br /> voltage and the polarity of the <br />(1) Nominal operating ac voltage grounded circuit conductor. <br />(2) Nominal operating ac frequency <br />(3) Maximum ac power 690.56 Identification of Power <br />(4) Maximum over current device Sources. <br />rating for ac module protection <br /> (A) Facilities with Stand-Alone Sys- <br />690.53 Photovoltaic Power Source. terns. Any structure or building with <br /> a photovoltaic power system that is <br />A marking, specifying the photo- not connected to a utility service <br />voltaic power source rated as fol- source and is a stand-alone system <br />lows, shall be provided by the in- shall have a permanent plaque or <br />staller at the site at an accessible directory installed on the exterior of <br />location at the disconnecting means the building or structure at a readily <br />for the photovoltaic power source: visible location acceptable to the au- <br /> thority having jurisdiction. The <br />(1) Operating current plaque or directory shall indicate the <br />(2) Operating voltage location of system disconnecting <br />(3) Maximum system voltage means and that the structure contains <br />(4) Short-circuit current a stand-alone electrical power sys- <br /> tem. <br />FPN: Reflecting systems used for <br />irradiance enhancement may result (B) Facilities with Utility Services <br />in increased levels of output cur- and PV Systems. Buildings or struc- <br />rent and power. tures with both utility service and a <br />__. <br />710-27 (Pleasanton April 2003) <br />