My WebLink
|
Help
|
About
|
Sign Out
2003 APRIL
City of Pleasanton
>
CITY CLERK
>
MUNICIPAL CODE SUPPLEMENTS
>
2003 APRIL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2009 2:04:58 PM
Creation date
7/13/2007 1:34:48 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
CODE SUPPLEMENTS
DOCUMENT DATE
2/20/2002
DOCUMENT NO
2003 APRIL
DOCUMENT NAME
SUPPLEMENT NO 12
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.24.120 <br />feet per sprinkler is required. A 500 <br />gallon per minute allowance for hose <br />streams shall also be provided. <br />5. Where the underside of roof <br />sheathing is twenty four (24') feet or <br />more to the finished floor, a sprin- <br />kler design of .60 gallons per minute <br />calculated over the hydraulically <br />most remote 3,000 square feet, with <br />a minimum sprinkler spacing of eight <br />by eight feet (8' X 8'). A 500 gallon <br />per minute allowance for hose <br />streams shall also be provided. <br />6. Where fire service booster and/or <br />fire pumps are required to meet fire <br />protection requirements, a minimum <br />of two (2) fire service booster and/or <br />fire pumps is required. Each fire <br />pump shall be powered by a diesel <br />engine. <br />(Ord. 1869 § 6, 2002; Ord. 1778 § 6, <br />1999; Ord. 1734 § 3, 1998) <br />20.24.130 UFC Section 1003.1.2.2 <br />Added -Installation Of <br />Fire Sprinkler Systems: <br />Section 1003.1.2.2 is added to the <br />Uniform Fire Code to read: <br />Section 1003.1.2.2 <br />A minimum design area of 3,000 <br />square feet shall be required for all <br />industrial/commercial sprinkler sys- <br />tems. Where subsequent occupancy <br />requires a sprinkler system of greater <br />design density or area of application <br />capability, it shall be the responsibil- <br />ity of the owner and/or occupant to <br />retrofit the sprinkler system to the <br />required code or standard in order to <br />obtain clearance for the new occu- <br />pancy or use. <br />(Ord. 1869 § 6, 2002; Ord. 1778 § 6, <br />1999; Ord. 1669 § 6, 1995) <br />20.24.140 UFC Section 1003.1.2.3 <br />Added -Installation Of <br />Fire Sprinkler Systems: <br />Section 1003.1.2.3 is added to the <br />Uniform Fire Code to read: <br />Section 1003.1.2.3 <br />Fire sprinkler protection shall be pro- <br />vided in all combustible and non- <br />combustible concealed spaces. <br />(Ord. 1869 § 6, 2002; Ord. 1806 § 2, <br />2000; Ord. 1778 § 6, 1999) <br />20.24.150 UFC Section 1003.3.1, <br />Where Required <br />Amended: <br />Section 1003.3.1 is amended to the <br />Uniform Fire Code to read as follows: <br />Section 1003.3.1 Where required. All <br />valves controlling the water supply <br />for automatic sprinkler systems and <br />water-flow switches on all sprinkler <br />systems shall be electrically moni- <br />tored as follows: <br />1. All fire protection and fire <br />alarm systems shall be supervised <br />to a Underwriters Laboratory (UL) <br />Central Station Service. Valve <br />monitoring, water-flow alarm(s), <br />FM 200 system(s), manual pull <br />stations, clean air suppression <br />systems, and trouble signal(s) etc. <br />shall be distinctly different and <br />shall be automatically transmitted <br />(Pleasanton April 2003) 710-46 <br />
The URL can be used to link to this page
Your browser does not support the video tag.