Laserfiche WebLink
20.24.150 <br />to an approved Underwriters Lab- <br />oratory (UL) Central Station Ser- <br />vice as specified in NFPA <br />72-1999 Edition. <br />and permit fee to the Livermore <br />Pleasanton Fire Department. The per- <br />mit shall be issued when the Depart- <br />ment determines that: <br />2. All Fire alarm system(s) alarm <br />initiation and signaling shall com- <br />ply with the provisions in Uni- <br />form Fire Code Section 1006. <br />Valve monitoring and water-flow <br />alarm and trouble signals shall be <br />distinctly different and shall be auto- <br />matically transmitted to an approved <br />central station, remote station or <br />proprietary monitoring station as <br />defined by national standards, or, <br />when approved by the building offi- <br />cial with the concurrence of the chief <br />of the fire department, sound an <br />audible signal at a constantly attend- <br />ed location. <br />(Ord. 1869 § 6, 2002; Ord. 1806 § 2, <br />2000) <br />20.24.160 UFC Section 1006.4 <br />Added -Fire Alarm <br />Company Permit And <br />Qualifications: <br />UFC Section 1006.4 is added to the <br />Uniform Fire Code to read: <br />Section 1006.4 <br />1. No person(s) may install or ser- <br />vice any fire alarm system or auto- <br />matic fire extinguishing system un- <br />less they have received a permit to <br />conduct such activity under the pro- <br />visions of this section. <br />2. To receive a permit, each per- <br />son(s) must submit an application <br />(a) The applicant has proper <br />equipment and is sufficiently quali- <br />fied to perform installation and ser- <br />vicing of fire alarm systems. <br />(b) The applicant meets the National <br />Alarm Code (NFPA 72-1999 Ed.) <br />requirements for the installation, <br />testing, inspection, and maintenance <br />of Central Station Service fire alarm <br />systems. The Fire Prevention Bureau <br />may grant exemptions from such re- <br />quirements where it determines that <br />an exemption is necessary to protect <br />public health, safety, and welfare. <br />Each installing company shall pro- <br />vide Underwriters Laboratory Central <br />Station Service and installer certifi- <br />cation number. <br />3. Every permit issued in accordance <br />with these provisions shall be valid <br />for a period of one (1) year from the <br />date of issuance. <br />4. Applications for renewal of a <br />permit shall be filed in the same <br />manner as for an original application <br />for permit. Each application shall be <br />accompanied by a renewal fee as <br />specified by resolution adopted by <br />City Council. <br />5. The Chief shall have the authority <br />to suspend or revoke a permit where <br />there is evidence of incompetence, <br />willful, or negligent fraud or failure <br />to perform properly and effectively <br />the duties assumed by the person <br />710-4"] (Pleasanton April 2003) <br />