Laserfiche WebLink
20.24.070 <br />4) Plans shall state that the instal- <br />lation will conform to the applica- <br />ble standards of the National Fire <br />Protection Association, State Fire <br />Marshal and demonstrate compati- <br />bility of devices and/or program- <br />ming as specified by manufactur- <br />ers of the equipment. <br />5) Plans must include a statement <br />of those tests which will be per- <br />formed to meet the minimum re- <br />quirements established by the <br />National Fire Protection Associa- <br />tion and State Fire Marshal. <br />The applicant shall keep a set of <br />approved plans at the installation site <br />for fire department use. Changes <br />from such plans may be approved by <br />the fire Prevention Bureau where <br />necessitated by on-site conditions. In <br />such instances a new plan, reflecting <br />the as-built installation, shall be sub- <br />mitted to the Bureau. All plan check- <br />ing in accordance with this section <br />shall be subject to a fee. <br />cluding tenant occupancy identi- <br />fication, as specified by the Fire <br />Prevention Bureau. <br />3. If available from the manufac- <br />turer(s) an on-site graphic annun- <br />ciator with reset and trouble si- <br />lence shall be provided at a loca- <br />tion(s) approved by the Fire Pre- <br />vention Bureau. All annunciation <br />location(s) shall be provided with <br />clear operational instructions, zone <br />information and site map. <br />4. Specialized fire suppression <br />equipment and specialized moni- <br />toring/detection equipment shall be <br />required to transmit alarm infor- <br />mation to the central station as <br />required by the Fire Prevention <br />Bureau. Examples include, but are <br />not limited to, halon, clean agent <br />fire extinguishing systems, hydro- <br />gen detection, highly toxic gas <br />detection systems, dry-pipe air <br />monitoring, heat and/or smoke <br />detection systems other than single <br />station devices, etc. <br />B. Alarm System Requirements. <br />All fire alarm or automatic fire extin- 5. All control valves for the auto- <br />guishing systems installed in accor- matic sprinkler system shall be <br />dance with this Article shall meet the electronically supervised and <br />following requirements: transmit status information to the <br />central station. <br />1. All fire sprinkler system(s) <br />alarm device, which may include 6. Final (as-built) plans including <br />water flow and valve tamper, shall a copy of "Alarm Information" <br />be connected to an approved U.L. shall be maintained and on file at <br />listed central station. the control panel or other on-site <br />location (key-lock box) approved <br />2. Sprinkler system design shall by the Fire Department. <br />incorporate zone annunciation, in- (Ord. 1669 § 6, 1995) <br />710-13 (Pleasanton 5-99) <br />