My WebLink
|
Help
|
About
|
Sign Out
1999 MAY
City of Pleasanton
>
CITY CLERK
>
MUNICIPAL CODE SUPPLEMENTS
>
1999 MAY
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2009 2:08:10 PM
Creation date
7/13/2007 3:20:01 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
CODE SUPPLEMENTS
DOCUMENT DATE
5/1/1999
DOCUMENT NO
1999 MAY
DOCUMENT NAME
SUPPLEMENT NO 8
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
380
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.24.120 <br />contents of the single tank or [v] Constructed of steel <br />cylinder of gas which presents with a thickness not less than <br />the highest potential hazard. 12-gauge. <br />[v] Systems utilized for <br />such processing shall be de- <br />signed as a treatment system, as <br />described in subsection (e)3 of <br />this section. If a total contain- <br />ment system is utilized, the <br />system shall be designed to <br />handle the maximum anticipated <br />pressure of release to the system <br />when the system reaches equi- <br />librium. <br />(2) Gas Cabinets. When gas <br />cabinets are provided they shall <br />be: <br />[i] Operated at negative <br />pressure in relation to the sur- <br />rounding area. <br />[ii] Provided with self- <br />closing limited access ports or <br />fire-rated windows to give ac- <br />cess to equipment controls. The <br />average velocity of ventilation <br />at the face of access ports or <br />windows shall be not less than <br />200 feet per minute (fpm) with <br />a minimum of 150 fpm at any <br />other point of the access port or <br />window. <br />[iii] Connected to a treat- <br />ment system. <br />(3) Treatment Systems. <br />[i] Treatment systems shall <br />be utilized to process all ex- <br />haust ventilation to be dis- <br />charged from gas cabinets, <br />exhausted enclosures or separate <br />storage rooms. Treatment sys- <br />tems shall be designed to reduce <br />the maximum allowable dis- <br />charge concentration of the gas <br />to one-half IDLH at the point of <br />discharge to the atmosphere as <br />specified in subsections (e)5 and <br />6 below. <br />[ii] When more than one <br />gas may be emitted to the treat- <br />ment system, the treatment <br />system shall be designed to <br />handle the worst case release <br />based on the release rate, the <br />quantity and the IDLH for all <br />the gases stored or used. <br />(4) Treatment System Sizing. <br />Treatment system shall be sized to <br />process the worst case release of <br />each gas based on the maximum <br />flow rate of release from the cylin- <br />der or tank utilized which presents <br />the highest potential hazard. The <br />entire contents of tanks and cylin- <br />ders shall be considered. <br />[iv] Provided with self- (5) Stationary Tanks. <br />closing doors. <br />710_27 (Pleasanton 5-99) <br />
The URL can be used to link to this page
Your browser does not support the video tag.