20.24.120 <br />[i] Stationary tanks shall <br />be labeled with the maximum <br />rate of release for the gas con- <br />tained based on any valves or <br />fittings that are inserted directly <br />into the tank. <br />[ii] If multiple valves or <br />fittings are provided, the maxi- <br />mum flow rate of release for the <br />valve or fitting with the highest <br />flow rate shall be indicated. If <br />liquefied gasses are in contact <br />with any valve or fitting, the <br />liquid flow rate shall be utilized <br />for purposes of computation of <br />the maximum flow rate of re- <br />lease. All flow rates indicated <br />on the label shall be converted <br />to cubic feet per minute of gas <br />at normal temperature and pres- <br />sure. <br />(6) Portable Tanks and Cylin- <br />ders. <br />[i] For portable tanks and <br />cylinders, the maximum flow <br />rate of release shall be calculat- <br />ed based on assuming the total <br />release from the cylinder or <br />tank within the time specified in <br />the Table below: <br />Non-liquefied Liquefied <br />Container Minutes Minutes <br />Cylinders 5 30 <br />Portable Tanks 40 240 <br />[ii] When portable tanks or <br />cylinders are equipped with ap- <br />proved reduced flow valves, the <br />worst case release will be deter- <br />mined by the maximum achiev- <br />able flow from the valve as <br />determined by the valve manu- <br />facturer or the gas supplier. Re- <br />duced flow and excess flow <br />valves shall be permanently <br />marked to indicate the maxi- <br />mum design flow rate. Such <br />markings shall indicate the flow <br />rate for air under standard con- <br />ditions. <br />(f) Exterior Storage. <br />(1) General. Persons responsible <br />for a facility where there is exteri- <br />or storage of any regulated materi- <br />al shall comply with the provisions <br />of this subsection (f) and of the <br />Uniform Building Code referenced <br />in the Pleasanton Municipal Code. <br />(2) Distance Limitation to Ex- <br />posures. Exterior storage of regu- <br />lated materials shall not be within <br />75 feet of a building, structure, <br />property line, street, alley, public <br />way or exit to a public way unless <br />the storage is shielded by a struc- <br />ture which has a minimum fire <br />resistive rating of two hours and <br />which interrupts the line of sight <br />between the storage and the expo- <br />sure. The shielding structure shall <br />be at least five (5) feet from any <br />exposure. The shielding structure <br />shall have not more than two sides <br />which shall be at approximately <br />90-degree directions. <br />(Pleasanton 5-99) '710_2,$ <br />