Laserfiche WebLink
20.08.043 <br />ground pool structure. When barriers <br />have horizontal members spaced less <br />than 45 inches (1143 mm) apart, the <br />horizontal members shall be placed <br />on the pool side of the barrier. Any <br />decorative design work on the side <br />away from the swimming pool, such <br />as protrusions, indentations or cut- <br />outs, which render the barrier easily <br />climbable, is prohibited. <br />(Ord. 1778 § 2, 1999) <br />20.08.044 Section 1701.5 Item 5.2 <br />Amended -Special <br />Moment-Resisting Steel <br />Frames: <br />Section 1701.5 item 5.2 of the Cali- <br />fornia Building Standards Code 1998 <br />Edition (24 CCR), and including by <br />reference the Uniform Building Code, <br />1997 Edition, parts 1, 2 and 3 is <br />amended to read as follows: <br />5.2 Special moment-resisting steel. <br />In Seismic Zones 3 and 4, and in <br />buildings in Seismic Zone No. 2 with <br />an importance factor I greater than <br />1.0, welded joints in Special, Ordi- <br />nary and Special Truss Moment <br />Frames; in Special and Ordinary <br />Concentrically Braced Frames, and in <br />Eccentrically Braced Frames that aze <br />part of the Lateral Force Resisting <br />System shall be inspected in accor- <br />dance with AISC Seismic Part I <br />Section 16. In addition to Item 5.1 <br />requirements, nondestructive testing <br />shall be as required by Section 1703 <br />of this code. <br />(Ord. 1778 § 2, 1999) <br />20.08.045 Section 904.1.2 <br />Amended -Standards - <br />Fire Extinguishing <br />Systems: <br />Section 904.1.2 of the California <br />Building Standazds Code 1998 Edition <br />(24 CCR), and including by reference <br />the Uniform Building Code parts 1, 2 <br />and 3 is amended to read as follows: <br />Standazds. Fire-extinguishing sys- <br />tems shall comply with City of <br />Pleasanton Sprinkler Standazd 9-3 <br />(1999 Edition) for one to fifteen <br />family dwelling units (not exceeding <br />12,000 sf in any one building), and <br />UBC Standard 9-1 for all other occu- <br />pancies. <br />(Ord. 1778 § 2, 1999; Ord. 1669 § 2, <br />1995) <br />20.08.046 Section 1703 First <br />Paragraph Only <br />Amended - <br />Nondestructive Testing: <br />Section 1703 of the California Build- <br />ing Standazds Code 1998 Edition (24 <br />CCR), and including by reference the <br />Uniform Building Code, 1997 Edition, <br />parts 1, 2 and 3 is amended to read as <br />follows: <br />1703. In Seismic Zones 3 and 4, <br />and in buildings in Seismic Zone No. <br />2 with an importance factor I greater <br />than 1.0, all complete-joint-penetra- <br />tion groove and partial-joint-penetra- <br />tion groove welded joints in Special, <br />Ordinary and Special Truss Moment <br />Frames; in Special and Ordinary <br />699 (Pleasanton April 2000) <br />