My WebLink
|
Help
|
About
|
Sign Out
2000 APRIL
City of Pleasanton
>
CITY CLERK
>
MUNICIPAL CODE SUPPLEMENTS
>
2000 APRIL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2009 2:07:22 PM
Creation date
7/13/2007 3:44:40 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
CODE SUPPLEMENTS
DOCUMENT DATE
4/1/2000
DOCUMENT NO
2000 APRIL
DOCUMENT NAME
SUPPLEMENT N0 9
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
174
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.08.046 <br />Concentrically Braced Frames, and in <br />Eccentrically Braced Frames that aze <br />subject to net tensile forces as part of <br />the Lateral Force Resisting System <br />shall be tested in accordance with <br />AISC Seismic Pazt I Section 16. This <br />testing shall be a part of the special <br />inspection requirements of Section <br />1701.5. A program for this testing <br />shall be established by the person <br />responsible for structural design and <br />as shown on plans and specifications. <br />(Ord. 1778 § 2, 1999) <br />20.08.048 Section 904.2 <br />Amended -Automatic Fire <br />Extinguishing Systems: <br />Section 904.2 of the California <br />Building Standazds Code 1998 Edition <br />(24 CCR), and including by reference <br />the Uniform Building Code parts 1, 2 <br />and 3, is amended to read as follows: <br />904.2. Automatic Fire Extinguishing <br />Systems <br />904.2.1 Where required. An auto- <br />matic fire extinguishing system shall <br />be installed in the occupancies and <br />locations as set forth in this section. <br />904.2 An automatic fire extinguish- <br />ing system or other approved fire <br />suppression system(s) shall be in- <br />stalled as follows: <br />1. In every story and basement of <br />all occupancies exceeding 8,000 <br />squaze feet. <br />Exceptions: <br />1. Group R, Division 3 Occu- <br />pancies. <br />2. Group U, Division 1 private <br />gazages of 1,000 square feet or <br />less. <br />3. Group U, Division 2 Occu- <br />pancles. <br />2. All buildings over 5 minutes <br />response time, as determined by <br />the Fire Chief, from a City fire <br />station. <br />3. Any structure in any area or <br />location determined by the Fire <br />Chief to be a high fire hazazd. <br />High fire hazazd azea shall be <br />defined as those areas beyond five <br />minutes driving time of fire <br />appazatus from the fire station <br />serving those particulaz districts; <br />or azeas determined by the Fire <br />Chief to be either high hazard <br />areas or extreme hazard azeas <br />based on steepness of slope and/or <br />fuel loadings from combustible <br />plant materials as set forth in the <br />Safety Element of the General <br />Plan. <br />(Ord. 1778 § 2, 1999; Ord. 1669 § 2, <br />1995) <br />20.08.049 City Of Pleasanton <br />Sprinter Standard 9-3: <br />Uniform Building Code Standazd 9-3 <br />amended--Installation of Sprinkler Sys- <br />tems in Residential Occupancies. <br />UBC Standard 9-3 is amended to <br />read as follows: <br />(Pleasanton April 2000) ']OQ <br />
The URL can be used to link to this page
Your browser does not support the video tag.