My WebLink
|
Help
|
About
|
Sign Out
2000 APRIL
City of Pleasanton
>
CITY CLERK
>
MUNICIPAL CODE SUPPLEMENTS
>
2000 APRIL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/20/2009 2:07:22 PM
Creation date
7/13/2007 3:44:40 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
CODE SUPPLEMENTS
DOCUMENT DATE
4/1/2000
DOCUMENT NO
2000 APRIL
DOCUMENT NAME
SUPPLEMENT N0 9
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
174
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20.08.049 <br />Syrinkler Svstem <br />An integrated system of piping con- <br />nected to a water supply, with listed <br />fire sprinklers which will automatically <br />initiate water discharge over a fire area. <br />When required, the fire sprinkler sys- <br />tem also includes a control valve, check <br />valve and a device for actuating an <br />alarm when the system operates. <br />check valve actuated by water flow in <br />one direction only. <br />Wet Svstem <br />A system employing automatic sprin- <br />klers attached to a piping system con- <br />taining water and connected to a water <br />supply so that water discharges imme- <br />diately from fire sprinklers opened by a <br />fire. <br />Standard <br />A document containing only mandatory <br />provisions using the word "shall" to <br />indicate requirements. Explanatory <br />material may be included only in the <br />form of "fine print" notes, in footnotes, <br />or in an Appendix. <br />Sunvly Pressure <br />Pressure within the supply (i.e., city or <br />private supply water sources). <br />Svstem Pressure <br />A pressure within the system (i.e., <br />above the control valve). <br />Water Flow Alarm <br />A sounding device activated by a water <br />flow detector or alarm check valve and <br />arranged to sound an alarm which will <br />be audible in all living areas over back- <br />ground noise levels with all intervening <br />doors closed. <br />Water Flow Detector <br />Sec. 9.106 <br />*The owner is responsible for the <br />condition of a sprinkler system and <br />shall keep the system in normal <br />operating condition at all times. <br />Sec. 9.107 <br />107.1 Devices and Materials <br />107.1.1 *Only new residential <br />sprinklers shall be used in sprinkler <br />systems. <br />107.1.2 Only listed and approved <br />devices and approved materials shall <br />be used in sprinkler systems. <br />Exceptions: Listing may be waived <br />for tanks, pumps, hangers, water <br />flow detection devices, and water <br />control valves. <br />107.1.3 Pre-engineered systems <br />shall be installed within the limita- <br />tions which have been established by <br />the testing laboratories where listed. <br />An electric signaling indicator or alarm 107.1.4 All systems shall be tested <br />'700_3 (Pleasanton April 2000) <br />
The URL can be used to link to this page
Your browser does not support the video tag.