My WebLink
|
Help
|
About
|
Sign Out
14
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2007
>
120407
>
14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2007 2:27:21 PM
Creation date
11/28/2007 12:27:52 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
STAFF REPORTS
DOCUMENT DATE
12/4/2007
DESTRUCT DATE
15 Y
DOCUMENT NO
14
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
locations where regulated materials are stored, handled and used, and be familiar with <br />the chemical nature of such material. An adequate number of personnel for each work <br />shift shall be designated. <br />Add Section 3704.1.14 to read: <br />3704.1.14 Emergency Drills. Emergency drills of the on-site emergency response team <br />shall be conducted on a regular basis but not less than once every three months. <br />Records of drills conducted shall be maintained. <br />Add section 3704.1.15 to read: <br />3704.1.15 Cylinder Leak Testing. Cylinders shall be tested for leaks immediately upon <br />delivery and again immediately prior to departure. Testing shall be approved by the fire <br />code official in accordance with appropriate nationally recognized industry standards <br />and practices, if any. Appropriate remedial action shall be immediately undertaken <br />when leaks are detected <br />Add Sec. 3704.1.16 to read: <br />3704.1.16 Inert Gas Purge System. Gas systems shall be provided with dedicated inert <br />gas purge systems. A dedicated inert gas purge system may be used to purge more <br />than one gas, provided the gases are compatible. Purge gas systems inside buildings <br />shall be located in an approved gas cabinet unless the system operates by vacuum <br />demand. <br />Add Sec. 3704.1.17 to read: <br />3704.1.17 Seismic Shutoff Valve. An automatic seismic shut-off valve, which is of a fail- <br />safe to close design, shall be provided to shutoff the supply of highly toxic, toxic and <br />moderately toxic gases with an LC50 less than 3000 parts per million upon a seismic <br />event within 5 seconds of a horizontal sinusoidal oscillation having a peak acceleration <br />of 0.3G (1.47m/sect) and a period of 0.4 seconds. <br />Amend Section 3704.2 to read: <br />3704.2 Indoor Storage and Use. The indoor storage or use of highly toxic, toxic and <br />moderately toxic compressed gases shall be in accordance with Sections 3704.2.1 <br />through 3704.2.2.10.3.3. The threshold quantity for highly toxic, toxic and moderately <br />toxic gases for indoor storage and use are set forth in Table 3704.2. <br />Add Table 3704.2 to read: <br />Threshold Quantities for Highly Toxic, Toxic and Moderately Toxic Gases <br />for Indoor Stora e and Use <br />Hi 1 Toxic 0 <br />Toxic 10 cubic feet <br />Moderatel Toxic 20 cubic feet <br />Amend Section 3704.2.1 to read: <br />99 <br />
The URL can be used to link to this page
Your browser does not support the video tag.