My WebLink
|
Help
|
About
|
Sign Out
14
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2007
>
120407
>
14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2007 2:27:21 PM
Creation date
11/28/2007 12:27:52 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
STAFF REPORTS
DOCUMENT DATE
12/4/2007
DESTRUCT DATE
15 Y
DOCUMENT NO
14
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3704.2.1 Applicability. The applicability of regulations governing the indoor storage and <br />use of highly toxic, toxic, and moderately toxic compressed gases shall be as set forth <br />in Sections 3704.2.1.1 through 3704.2.1.3. <br />Amend Sec. 3704.2.1.1 to read: <br />3704.2.1.1 Quantities Not Exceeding the Maximum Allowable Quantity per Control <br />Area. The indoor storage or use of highly toxic, toxic and moderately toxic gases in <br />amounts exceeding the threshold quantity per control area set forth in Table 3704.2 <br />shall be in accordance with Sections 2701, 2703, 3701, 3704.1 and 3704.2, <br />Amend Sec. 3704.2.2 to read: <br />3704.2.2 General Indoor Requirements. The general requirements applicable to the <br />indoor storage and use of highly toxic and toxic compressed gases shall be in <br />accordance with Sections 3704.2.2.1 through 3704.2.2.10.3. <br />Moderately toxic gases with an LC50 less than 3000 parts per million shall comply with <br />the requirements for toxic gases in Sections 3704.2.2.1 through 3704.2.2.10.3 <br />All other moderately toxic gases exceeding the threshold quantity shall comply with the <br />requirements for toxic gases in Sections 3704.2.2.1 through 3704.2.2.7. <br />Amend Sec. 3704.2.2.7 to read: <br />3704.2.2.7 Treatment Systems. The exhaust ventilation from gas cabinets, exhausted <br />enclosures, gas rooms and local exhaust systems required in Section 3704.2.2.4 and <br />3704.2.2.5 shall be directed to a treatment system. The treatment system shall be <br />utilized to handle the accidental release of gas and to process exhaust ventilation. The <br />treatment system shall be designed in accordance with Sections 3704.2.2.7.1 through <br />3704.2.2.7.5 and Section 505 of the California Mechanical Code. <br />EXCEPTIONS:: <br />1. Highly toxic, toxic and moderately toxic gases storage. A treatment system is not <br />required for cylinders, containers and tanks in storage when all of the following are <br />provided: <br />1.1 Valve outlets are equipped with gas-tight outlet plug or caps. <br />1.2 Hand wheel-operated valves have handles secured to prevent movement. <br />1.3 Approved containment vessels or containment systems are provided in <br />accordance with Section 3704.2.2.3. <br />Amend 3704.2.2.10.1 to read: <br />3704.2.2.10.1. Alarms. The gas detection system shall initiate a local alarm and <br />transmit a signal to a constantly attended control station when ashort-term hazard <br />condition is detected. The alarm shall be both visual and audible and shall provide <br />warning both inside and outside the area where the gas is detected. The audible alarm <br />shall be distinct from all other alarms. <br />Amend Section 3704.3 to read: <br />ioo <br />
The URL can be used to link to this page
Your browser does not support the video tag.