My WebLink
|
Help
|
About
|
Sign Out
14
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2007
>
120407
>
14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2007 2:27:21 PM
Creation date
11/28/2007 12:27:52 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
STAFF REPORTS
DOCUMENT DATE
12/4/2007
DESTRUCT DATE
15 Y
DOCUMENT NO
14
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
equipment that will provide emergency radio coverage acceptable to the fire code <br />official shall be install. <br />20.24.050 CFC Chapter 6 amended -Building Services and Systems. <br />CFC Section 603.4.2 is added: <br />603.4.2 Portable Un-vented Heaters Used in Other Occupancies and Outside <br />Locations. Use of portable un-vented heaters in other occupancies and outside <br />locations shall be approved by the fire code official. <br />20.24.060 CFC Chapter 6 amended -Building Services and Systems. <br />CFC Section 605.11 is added: <br />605.11 Immersion Heaters. All electrical immersion heaters used in dip tanks, sinks, <br />vats and similar operations shall be provided with approved over-temperature controls <br />and low liquid level electrical disconnects. Manual reset of required protection devices <br />shall be provided. <br />20.24.070 CFC Chapter 6 added -Building Services and Systems. <br />CFC Section 608.6.3 is added: <br />608.6.3 Failure of Ventilation System. Failure of the ventilation system shall <br />automatically disengage the charging system. <br />20.24.080 CFC Section 903.2 amended -Fire Extinguishing Systems-Where required. <br />CFC Section 903.2 is amended: <br />903.2 An automatic fire extinguishing system or other approved fire suppression <br />system(s) shall be installed as follows: <br />1. In every building where the floor and basement area exceeds 8000 square feet. <br />Exceptions: <br />1. Group U, Division 1 private garages of 1,000 square feet or less. <br />2. Group U, Division 2 Occupancies. <br />2. In all buildings of all occupancies except Groups R1, R3 and U occupancies on a <br />parcel when the building(s) area(s) on the parcel exceeds 8,000 square feet of floor <br />area, including area of basements. <br />3. All buildings residential or commercial over 5 minutes response time, as determined <br />by the Fire chief, from a City fire station. <br />4. Any structure in any area or location determined by the Fire Chief to be a high fire <br />hazard. High fire hazard area shall be defined as those areas beyond five minutes <br />83 <br />
The URL can be used to link to this page
Your browser does not support the video tag.