driving time of fire apparatus from the fire station serving those particular districts; or <br />areas determined by the Fire Chief to be either high hazard areas or extreme hazard <br />areas based on steepness of slope and/or fuel loadings from combustible plant <br />materials as set forth in the Safety Element of the General Plan. <br />5. In every story or basement of all buildings when the floor area exceeds 1,500 <br />square feet (139.4 m2) and there is not provided at least 20 square feet (1.86 m2) of <br />opening entirely above the adjoining ground level in each 50 lineal feet (15 240 mm) or <br />fraction thereof of exterior wall in the story or basement on at least one side of the <br />building. Openings shall have a minimum dimension of not less than 30 inches (762 <br />mm). Such openings shall be accessible to the fire department from the exterior and <br />shall not be obstructed in a manner that firefighting or rescue cannot be accomplished <br />from the exterior. When openings in a story are provided on only one side and the <br />opposite wall of such story is more than 75 feet (22 860 mm) from such openings, the <br />story shall be provided with an approved automatic sprinkler system, or openings as <br />specified above shall be provided on at least two sides of an exterior wall of the story. <br />If any portion of a basement is located more than 75 feet (22 860 mm) from openings <br />required in this section, the basement shall be provided with an approved automatic <br />sprinkler system. <br />6. At the top of rubbish and linen chutes and in their terminal rooms. Chutes extending <br />through three or more floors shall have additional sprinkler heads installed within such <br />chutes at alternate floors. Sprinkler heads shall be accessible for servicing. <br />7. In rooms where nitrate film is stored or handled. <br />8. In protected combustible fiber storage vaults as defined in the Fire Code. <br />9. Throughout all buildings with a floor level with an occupant load of 30 or more that is <br />located 55 feet (16 764 mm) or more above the lowest level of fire department vehicle <br />access. <br />EXCEPTION: 1. Airport control towers. <br />20.24.090 CFC Sections 903.2.1 Group A. through 903.2.17 -Fixed guideway transit <br />systems. <br />Delete these sections. <br />20.24.100 CFC Section 903.3.1.1.1 -Exempt locations. <br />Sections 903.3.1.1.1.3 and Section 903.3.1.1.1.4 are deleted. <br />20.24.110 CFC Section 903.3.1A added -NFPA 13 sprinkler systems. <br />CFC Section 903.3.1A is added. <br />Section 903.3.1 A <br />1. This Section applies to all new and existing buildings. <br />84 <br />