My WebLink
|
Help
|
About
|
Sign Out
15 ATTACHMENT 9
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2008
>
031808
>
15 ATTACHMENT 9
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2008 1:56:39 PM
Creation date
3/14/2008 4:54:38 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
STAFF REPORTS
DOCUMENT DATE
3/18/2008
DESTRUCT DATE
15 Y
DOCUMENT NO
15 ATTACHMENT 9
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
380
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project No. 9929.G Geotechnical Investigation/Vineyard Avenue, Pleasanton 8 August 2003 <br />57. Retaining walls or sound walls may either be founded on a spread footing or a pier <br />foundation. A spread footing foundation may only be used where there is a minimum of 10 feet <br />of cover between the slope surface and the front face of the footing at foundation level. Spread <br />footings should have a minimum depth of 18 inches below the lowest adjacent pad grade (i.e. <br />trenching depth). Design bearing pressures for footings should not exceed 2,200 p.s.f. due to <br />dead plus sustained live loads and maybe increased by 113 due to all loads which include wind or <br />seismic. To accommodate lateral building loads, the passive resistance of the foundation soil can <br />be utilized. The passive soil pressures can be assumed to act against the front face of the footing <br />below a depth of one foot below the ground surface or driveway subgrade. It is recommended <br />that a passive pressure equivalent to that of a fluid weighing 275 p.c.f. be used. In addition, an <br />allowable friction coefficient of 0.30 can be assumed at the base of the spread footings. <br />58. Piers should be designed on the basis of skin friction acting between the soil and that <br />portion of the pier that extends below a depth of two feet below finished grade. For the soils at <br />the site, an allowable skin friction value of 400 p.s.f. can be used for combined dead and live <br />loads. This value can be increased by one-third for total loads which include wind or seismic <br />forces. Spacing should be determined as required by the load distribution, but minimum spacing <br />should not be less than 3 pier diameters, center to center. Maximum spacing and the minimum <br />depth of piers is to be determined by the Structural Engineer. <br />59. To resist lateral loads, the passive resistance of the soil can be used. The soil passive <br />pressures can be assumed to act against the lateral projected area of the pier described by the <br />vertical dimension of twice the pier diameter. It is recommended that a passive pressure <br />equivalent of that of a fluid weighing 275 p.c.f. be used below one foot. <br />60. It is important that care be exercised to ensure that any concrete spills during the concrete <br />pour must be removed and no "mushrooming" effects are allowed to remain around the top of the <br />pier. <br />TERRASEARCH, inc. Page 27 of 53 <br />
The URL can be used to link to this page
Your browser does not support the video tag.