Laserfiche WebLink
C CORNERSTONE <br />EARTH GROUP <br />7.2 MAT FOUNDATIONS <br />7.2.1 Post-Tensioned Mats <br />In our opinion, the proposed residential structures may be supported on post-tensioned mat <br />foundations provided the recommendations in the "Earthwork" section and the sections below <br />are followed. Post-tensioned (PT) concrete mat foundations may be designed in accordance <br />with the parameters in the table below based on procedures developed by the Post-Tensioning <br />Institute (latest edition) and as referenced in the 2007 California Building Code. <br />Table 6: Post-Tensioned Mat Design Criteria <br />Differential Movement Condition Center Lift Edge Lift <br />Edge Moisture Variation (feet) 5.5 3.0 <br />Differential Soil Movement (inches) 0.5 0.8 <br />To reduce potential differential movement, all mats should be designed for a maximum average <br />allowable bearing pressure of 750 psf for dead plus live loads; at column or wall loading, the <br />maximum localized bearing pressure should be limited to 2,500 psf. When evaluating wind and <br />seismic conditions, allowable bearing pressures may be increased byone-third. These <br />pressures are net values; the weight of the mat may be neglected for the portion of the mat <br />extending below grade. Top and bottom mats of reinforcing steel should be included as <br />required to help span irregularities and differential settlement. <br />7.2.2 Mat Foundation Settlement <br />We estimate that total foundation movement under static loads will be less than'/: inch, with <br />post-construction differential movement of less than %2 inch across the building footprint. <br />7.2.3 Lateral Loading <br />Lateral loads may be resisted by friction between the bottom of mat foundation and the <br />supporting subgrade, and also by passive pressures generated against deepened mat edges. <br />An ultimate frictional resistance of 0.4 applied to the mat dead load, and an ultimate passive <br />pressure based on an equivalent fluid pressure of 450 pcf may be used in design. The <br />structural engineer should apply an appropriate factor of safety (such as 1.5) to the ultimate <br />values above. The upper 12 inches of soil should be neglected when determining passive <br />pressure capacity. <br />7.2.4 Moisture Protection Considerations for Mat Foundations <br />The following general guidelines for concrete mat construction where floor coverings are <br />planned are presented for the consideration by the developer, design team, and contractor. <br />Ponderosa Active Adult Community Page 18 <br />132-2-1 <br />