My WebLink
|
Help
|
About
|
Sign Out
09 ATTACHMENTS
City of Pleasanton
>
CITY CLERK
>
AGENDA PACKETS
>
2009
>
021709
>
09 ATTACHMENTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2009 1:21:44 PM
Creation date
2/12/2009 4:35:29 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
STAFF REPORTS
DOCUMENT DATE
2/17/2009
DESTRUCT DATE
15 Y
DOCUMENT NO
09 ATTACHMENTS
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
314
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
would meet the General Plan noise standards and noise mitigation is not required for these noise <br />sources. Nevertheless, the project has been conditioned to provide disclosure to buyers of the <br />proximity to the airport and overflights. <br />The project site is exposed to intermittent noise from the City's Operations Service Center. The <br />noise study indicated that the police firing range, which is located approximately 630 feet from <br />the project's southern boundary, would be the most significant noise source from the OSC. The <br />noise study indicates that gunshot noise is significantly more annoying than traffic noise at the <br />same level. The noise study recommends that noise levels from gunshots be reduced to not <br />exceed 40 dBA Lm~ inside the residences with the windows and exterior doors closed. In order <br />to meet this interior noise standard, the windows and exterior doors on the east, west, and south <br />sides of the homes on Lots 3, 4, and 91-96 would need to provide at least 25 dBA of noise <br />reduction on the first floor and provide at least 35 dBA of noise reduction on the second floor. <br />These homes would also need to be provided with forced air mechanical ventilation (i.e., air <br />conditioning) so that windows and doors may be closed at the discretion of the occupants to <br />control noise. The exact Sound Transmission Class (STC) ratings of the windows and doors to <br />meet these requirements would be determined at the building permit stage. A condition of <br />approval requires that the applicant comply with the recommendations of the noise study. <br />Noise Impacts on Adjacent Properties <br />The development of residential uses on the property will generate added urban noise, such as <br />traffic, landscape maintenance activities, etc. However, noise levels will not change <br />substantially from that currently experienced in the area. <br />Short-term construction noise would be generated during any new construction of this site. The <br />City normally allows construction hours from 8:00 a.m. to 5:00 p.m., Monday through Friday, <br />with Saturday construction allowed if there are no nearby residents that could be impacted by <br />construction noise or activities. Since there are existing residences directly adjacent to the <br />proposed project site, staff is not recommending that Saturday construction be allowed. Staff is <br />recommending a condition that would allow the Director of Planning and Community <br />Development to approve earlier construction "start times" or later "stop times" only for specific <br />construction activities (e.g., concrete foundation/slab pours) if it can be demonstrated to the <br />satisfaction of the Director of Planning and Community Development that that the construction <br />and construction traffic noise will not impact nearby residents. Construction equipment would <br />be required to meet DMV noise standards and be equipped with muffling devices. <br />Gradine Plan <br />The subject property generally has flat terrain. Site grades generally range from an elevation of <br />352 feet at the south end of the site to an elevation of 361 feet at the northeast corner. Grading <br />for the proposed project would be limited to that required for preparation of the building pads <br />and foundations, streets, and utilities. Retaining walls from 1.2 to five feet in height would be <br />PUD-74 Page -12 - June 25, 2008 <br />
The URL can be used to link to this page
Your browser does not support the video tag.