Laserfiche WebLink
pLE A <br />Project Name: <br />Project Location: <br />Date: <br />Comments by: <br />Project Planner: <br />THE CITY OF <br />Civic Center Apartments <br />4800 Bernal Avenue <br />March 9, 2009 <br />Natalie Amos <br />Marion Pavan <br />RE: Multifamily GreenPoint Checklist <br />1 <br />ATTACHMENT 11 <br />The following are staffs comments regarding the Multifamily GreenPoint checklist (2005 Edition <br />v.2) for the proposed development project located at 4800 Bernal Avenue, Civic Square <br />Apartments. Staff's comments are intended to assist you in meeting the City's Residential <br />Green Building Ordinance (17.50) requirements. <br />Staff's comments are provided in the following sections: General Comments, Required <br />Measures /Points, Achieved Points, Discounted Points, Potential Points, Points to <br />Consider, and Summary. Missing and /or additional information /documentation /plans noted in <br />any of the sections may be provided to staff upon submittal of plan check to the Building and <br />Safety Division. The Community Development Director, or his designee, may require <br />missing /additional information prior to submitting to the Building and Safety Division (i.e. prior <br />to Planning approval). <br />GENERAL COMMENTS <br />Project data information (i.e. parcel square- footage, existing square- footage of buildings, <br />proposed square- footage of buildings, open space square- footage, etc.) was not provided on <br />the plans, thus, staff cannot verify the "Percent of Project Dedicated to Residential Use <br />Project data information necessary to verify the "Total Conditioned Floor Area of the Project" <br />and the "Total Non Residential Floor Area of Project" is required to be provided on the plans <br />upon submittal to the Building and Safety Division. Staff will reevaluate this section of the <br />checklist upon receipt of this information. <br />REQUIRED MEASURES /POINTS <br />The following points are required per the Build It Green GreenBuilding Checklist and the City <br />of Pleasanton. These points shall be reflected on the plans or (when applicable) through <br />supporting documentation prior to submitting to the Building and Safety Division for plan check. <br />A.8.a A Title 24 report showing the percentage above code in the form CF -1 R for low -rise <br />residential buildings. The final simulation report (approved by the Building and <br />Safety Division) must be used to show evidence of exceeding Title 24. The report <br />must include actual building components and HVAC systems included in the final <br />building design (i.e. simulation is run off of plans at least at the 100% Construction <br />Documents phase). If more than one Title 24 report is available for the residential <br />portions of the project, enter the combined weighted average (based on square <br />footage) of percent above code for the various reports. <br />