Laserfiche WebLink
City of Pleasanton <br />475 and 493 St. John Street Mixed-Use Project <br /> <br />40 <br />As determined in the Final EIR for the DSP, the DSP area does not overlie a known earthquake fault <br />or landslide hazards areas; therefore, the proposed project would not cause potential substantial <br />adverse effects, including the risk of loss, injury, or death involving rupture of a known earthquake <br />fault or landslides. However, as discussed in the Final EIR, the DSP area is within a seismically active <br />region, and the proposed project would be subject to strong seismic ground shaking. Risks <br />associated with ground shaking would be minimized by compliance with CBC engineering design and <br />construction measures, which require foundations and other structural support features to resist or <br />absorb damaging forces from strong ground shaking. Although nothing can ensure that proposed <br />structures do not fail under seismic stress, proper engineering can minimize the risk to life and <br />property. Additionally, as described above, the project would be required to incorporate <br />recommendations made in the Geotechnical Investigation. These recommendations would minimize <br />the impacts of ground shaking, including but not limited to recommendations for subgrade <br />preparation, materials for fill, compaction of fill, and foundation construction, and the impacts of <br />localized erosion along Arroyo del Valle (Appendix D). <br />The Geotechnical Investigation identified that some subsurface soils at the project site are prone to <br />liquefaction during seismic ground shaking. The Geotechnical Investigation recommends including <br />post-tensioned slab foundations in proposed structures, which would accommodate settlement <br />during liquefaction (Appendix D). Additionally, the Geotechnical Investigation includes other <br />recommendations to reduce risks associated with liquefaction, including but not limited to soil <br />moisture content control and selection of fill material. As described above, the project would be <br />required to incorporate recommendations made in the Geotechnical Report, and risks associated <br />with liquefaction would be minimized to the extent feasible. Therefore, the project would not cause <br />potential substantial adverse effects, including the risk of loss, injury, or death involving <br />liquefaction. Impacts would be less than significant. <br />As described further in Section 4.8, Hydrology, Drainage, and Water Quality, the project site is <br />greater than one acre and would be subject to the National Pollutant Discharge Elimination System <br />(NPDES) General Permit for Storm Water Discharges Associated with Construction and Land <br />Disturbance Activities (Order No. 2022-0057-DWQ) adopted by the State Water Resources Control <br />Board (SWRCB). Compliance with the NPDES permit requires each qualifying development project to <br />file a Notice of Intent with the SWRCB. Permit conditions require the development of a stormwater <br />pollution prevention plan (SWPPP), which must describe the site, the facility, erosion and sediment <br />controls, runoff water quality monitoring, means of waste disposal, implementation of approved <br />local plans, control of construction sediment and erosion control measures, maintenance <br />responsibilities, and non-stormwater management controls. Inspection of construction sites before <br />and after storms is also required to identify stormwater discharge from the construction activity and <br />to identify and implement erosion controls, where necessary. Compliance with the Construction <br />General Permit is reinforced through the PMC in Chapter 9.14, Stormwater Management and <br />Discharge Control. Section 9.14.090(b)(3) of this chapter prohibits development within 20 feet of <br />the top of a bank or within 30 feet of the creek centerline unless a written permit has been obtained <br />from the Public Works Director. The project would be required to include recommendations made <br />within the Geotechnical Investigation, including the installation of stitch piers along the top of the <br />existing creek bank to retain the soil and surcharge forces from behind the piers. Compliance with <br />the Construction General Permit and PMC would ensure that the project would not result in <br />substantial soil erosion or the loss of topsoil. Impacts would be less than significant.