My WebLink
|
Help
|
About
|
Sign Out
AGENDA FULL PACKET
City of Pleasanton
>
BOARDS AND COMMISSIONS
>
PLANNING
>
AGENDA PACKETS
>
2020 - PRESENT
>
2024
>
10-23
>
AGENDA FULL PACKET
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/6/2024 11:08:57 AM
Creation date
11/6/2024 10:59:50 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - TYPE
AGENDA REPORT
DOCUMENT DATE
10/23/2024
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
531
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Environmental Impacts of the Proposed Changes to the Original Project <br /> <br />Addendum to the City of Pleasanton Downtown Specific Plan Final Environmental Impact Report 53 <br />equivalent to sound pressure level (SPL) of 65 dBA at 3 feet (see Appendix F for manufacturer’s <br />specifications). <br />Pursuant to PMC Section 9.04.030 and 9.04.040, project impacts would be significant if exterior <br />noise levels exceed 60 dBA at a residential property and 70 dBA at a commercial property at any <br />point outside of the property plane. For purposes of this analysis, the closest three units to the <br />sensitive receptor were analyzed. Rooftop mounted HVAC units would be located as close as 140 <br />feet from the nearest residential property west of the project site, and 20 feet from the commercial <br />properties east of the project. Combined noise levels of three HVAC units generated by rooftop <br />HVACs would be approximately 47 dBA Leq at 140 feet and 66 dBA Leq at 20 feet, which would not <br />exceed exterior daytime and nighttime noise standards of 60 dBA Leq for residential properties and <br />70 dBA Leq for commercial properties. Ground-mounted HVAC units on the proposed residential <br />units would be located as close as 15 feet to the residential property to the west. Noise levels of a <br />residential HVAC unit would be approximately 51 dBA Leq at 15 feet to the residential property to <br />the west, which would not exceed the exterior daytime and nighttime noise standard of 60 dBA Leq <br />at residential properties. In addition, this is a conservative analysis that does not consider possible <br />mechanical equipment shielding or attenuated from the rooftop edges. Therefore, impacts related <br />to HVAC equipment noise would be less than significant. <br />TRAFFIC NOISE <br />The Trip Generation Assessment prepared by the City of Pleasanton was used to estimate traffic <br />noise associated with the project. Refer to Section 5.12, Traffic and Transportation, for the Trip <br />Generation Assessment. As discussed in Section 5.12, Traffic and Transportation, and shown in <br />Table 10, the net vehicle trips would decrease, given the removal of the existing restaurant currently <br />occupying the project site The project would not make substantial alterations to roadway <br />alignments or substantially change the vehicle classifications mix on local roadways. Therefore, the <br />primary factor affecting off-site noise levels would be increased traffic volumes. <br />In order for a barely perceptible noise increase of at least 3 dBA to occur, the project would need to <br />result in a doubling of traffic on the affected road segment. Given that vehicle trips generated on <br />the project site would decrease as a result of the project (see Section 5.12, Traffic and <br />Transportation), traffic noise on local roadways, such as St. John Street, would also decrease. <br />Therefore, the traffic noise from the project would not result in a noise level increase and traffic <br />noise would be below the barely perceptible noise increase of 3 dBA and impacts would be less than <br />significant. <br />Airport Noise <br />The project site remains outside the vicinity of an airport land use plan, public airport, or private <br />airstrip, and no impact would occur. <br />Effects and Mitigation Measures <br />No new or substantially more severe significant effects would occur related to noise compared with <br />those identified in the Final EIR, and no new or revised mitigation measures are necessary. The Final <br />EIR would continue to apply to the Barone’s project. Operational and construction noise impacts <br />would remain less than significant and would not require mitigation.
The URL can be used to link to this page
Your browser does not support the video tag.